Changes in sevoflurane plasma concentration with delivery through the oxygenator during on-pump cardiac surgery.
Nitzschke, R; Wilgusch, J; Kersten, J F; Trepte, C J; Haas, S A; Reuter, D A; Goetz, A E; Goepfert, M S.
Afiliação
  • Nitzschke R; Department of Anaesthesiology, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, Hamburg 20246, Germany. r.nitzschke@uke.de
Br J Anaesth ; 110(6): 957-65, 2013 Jun.
Article em En | MEDLINE | ID: mdl-23462192
ABSTRACT

BACKGROUND:

It is unclear what factors affect the uptake of sevoflurane administered through the membrane oxygenator during cardiopulmonary bypass (CPB) and whether this can be monitored via the oxygenator exhaust gas.

METHODS:

Stable delivery of sevoflurane was administered to 30 elective cardiac surgery patients at 1.8 vol% (inspiratory) via the anaesthetic circuit and ventilator. During CPB, sevoflurane was administered in the oxygenator fresh gas supply (Compactflo Evolution™; Sorin Group, Milano, Italy). Sevoflurane plasma concentration (SPC) was measured using gas chromatography. Changes were correlated with bispectral index (BIS), patient temperature, haematocrit, plasma albumin concentration, oxygenator fresh gas flow, and the sevoflurane concentration in the oxygenator exhaust at predefined time points.

RESULTS:

The mean SPC pre-bypass was 54.9 µg ml(-1) [95% confidence interval (CI) 50.6-59.1]. SPC decreased to 43.2 µg ml(-1) (95% CI 40.3-46.1; P<0.001) after initiation of CPB, and was lower still during rewarming and weaning from bypass, 39.4 µg ml(-1) (95% CI 36.6-42.3; P<0.001). BIS did not exceed a value of 55. SPCs were higher during hypothermia (P<0.001) and with an increase in oxygenator fresh gas flow (P=0.015), and lower with haemodilution (P=0.027). No correlation was found between SPC and the concentration of sevoflurane in the oxygenator exhaust gas (r=-0.04; 95% CI -0.18 to 0.09; P=0.53).

CONCLUSIONS:

The uptake of sevoflurane delivered via the membrane oxygenator during CPB seems to be affected by hypothermia, haemodilution, and changes in the oxygenator fresh gas supply flow. Measuring the concentration of sevoflurane in the exhaust from the oxygenator is not useful for monitoring sevoflurane administration during bypass.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Oxigenadores de Membrana / Ponte Cardiopulmonar / Anestésicos Inalatórios / Procedimentos Cirúrgicos Cardíacos / Éteres Metílicos Tipo de estudo: Observational_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Br J Anaesth Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Oxigenadores de Membrana / Ponte Cardiopulmonar / Anestésicos Inalatórios / Procedimentos Cirúrgicos Cardíacos / Éteres Metílicos Tipo de estudo: Observational_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Br J Anaesth Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Alemanha