ABSTRACT

AIMS:

This study aimed to validate automatic intravascular optical coherence tomography (IVOCT) analysis for the evaluation of neointimal coverage in response to stent implantation. METHODS AND

RESULTS:

Fourteen stented segments in common iliac arteries, acquired from a total of seven adult male New Zealand White rabbits, were interrogated in vivo by IVOCT. Durable polymer everolimus-eluting stents (EES; Xience V, Abbott Vascular, Santa Clara, CA, USA) were used exclusively. Comparison with histology was made in a total of 63 pairs of images, where neointimal thickness over corresponding individual stent struts was assessed. A high correlation coefficient (R = 0.85, P < 0.001) was obtained by comparing automatic IVOCT analysis with histology. Moreover, Bland-Altman statistics showed good limits of agreement (LOAs) of ±45 µm, with an average difference of -10 µm. In addition, manual IVOCT assessment presented very similar results when compared with histology (R = 0.83, P < 0.001 and LOA = ±48 µm with an average difference of -8 µm). Therefore, a very high correlation value was found, comparing manual to automatic IVOCT measurements (R = 0.95, P < 0.001) together with good LOAs (±27 µm) and an average difference of -2 µm.

CONCLUSION:

The results of the study suggest that automatic IVOCT analysis is a reliable and accurate tool able to speed up current IVOCT analysis procedures. This would potentially allow for a better integration of IVOCT in clinical practice and clinical studies assessing vascular response to stent implantation in a large series of patients.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia de Coerência Óptica / Stents Farmacológicos / Neointima Tipo de estudo: Guideline Limite: Animals Idioma: En Revista: Eur Heart J Cardiovasc Imaging Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Bélgica

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia de Coerência Óptica / Stents Farmacológicos / Neointima Tipo de estudo: Guideline Limite: Animals Idioma: En Revista: Eur Heart J Cardiovasc Imaging Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Bélgica