Your browser doesn't support javascript.
loading
Retention assessment of magnetic nanoparticles in rat arteries with micro-computed tomography.
Tu, Shu-Ju; Wu, Siao-Yun; Wang, Fu-Sheng; Ma, Yunn-Hwa.
Afiliação
  • Tu SJ; Department of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, Tao-Yuan, Taiwan.
Phys Med Biol ; 59(5): 1271-81, 2014 Mar 07.
Article em En | MEDLINE | ID: mdl-24556757
Magnetic nanoparticles (MNPs) may serve as carriers for pharmacological agents to the target in a magnetic-force guiding system. It is essential to achieve effective retention of MNPs through the external magnet placement. However, it is difficult to estimate the retention efficiency of MNPs and validate the experimental strategies. Micro-CT was used to identify the spatial distribution of MNP retention and image analysis is then extended to evaluate the MNP delivery efficiency. Male Sprague Dawley rats were anesthetized to expose abdominal arteries with an NdFeB magnet of 4.9 kG placed by the left iliac artery. After a 20 min equilibrium period, arteries were ligated, removed and fixed in a paraformaldehyde solution. Experiments were performed with intravenous injection in our platform with two independent groups. MNPs were used in the first group, while chemical compounds of recombinant tissue plaminogen activator were attached to MNPs as rtPA (recombinant tissue plaminogen activator)-MNPs in the second group. Image analysis of micro-CT shows the average retention volume of MNPs and rtPA-MNPs in the left iliac arteries is 9.3 and 6.3 fold of that in the right. Large local aggregation of MNPs and rtPA-MNPs in the left iliac arteries is the consequence of external magnet placement, suggesting feasibility of magnetic targeting through the intravenous administration. We also determined that on average 0.57% and 0.064% of MNPs and rtPA-MNPs respectively were retained in the left iliac artery. It was estimated that the average rtPA concentration of 60.16 µg mL(-1) may be achieved with rtPA-MNPs. With the micro-CT imaging approach, we accomplished visualization of the aggregation of retained particles; reconstructed 3D distribution of relative retention; estimated the average particle number of local retention; determined efficiency of targeted delivery. In particular, our quantitative image assessment suggests that intravenous administration of rtPA-MNPs may retain local concentration of rtPA high enough to induce thrombolysis.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aorta Abdominal / Angiografia / Tomografia Computadorizada por Raios X / Nanopartículas de Magnetita Limite: Animals Idioma: En Revista: Phys Med Biol Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Taiwan

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aorta Abdominal / Angiografia / Tomografia Computadorizada por Raios X / Nanopartículas de Magnetita Limite: Animals Idioma: En Revista: Phys Med Biol Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Taiwan