Your browser doesn't support javascript.
loading
MRI-based computational fluid dynamics for diagnosis and treatment prediction: clinical validation study in patients with coarctation of aorta.
Goubergrits, Leonid; Riesenkampff, Eugenie; Yevtushenko, Pavlo; Schaller, Jens; Kertzscher, Ulrich; Hennemuth, Anja; Berger, Felix; Schubert, Stephan; Kuehne, Titus.
Afiliação
  • Goubergrits L; Biofluid Mechanics Laboratory, Charité-Universitätsmedizin, Berlin, Germany; Non-Invasive Cardiac Imaging in Congenital Heart Disease Unit, Charité-Universitätsmedizin, Berlin, and German Heart Institute, Berlin, Germany.
J Magn Reson Imaging ; 41(4): 909-16, 2015 Apr.
Article em En | MEDLINE | ID: mdl-24723299
ABSTRACT

PURPOSE:

To reduce the need for diagnostic catheterization and optimize treatment in a variety of congenital heart diseases, magnetic resonance imaging (MRI)-based computational fluid dynamics (CFD) is proposed. However, data about the accuracy of CFD in a clinical context are still sparse. To fill this gap, this study compares MRI-based CFD to catheterization in the coarctation of aorta (CoA) setting. MATERIALS AND

METHODS:

Thirteen patients with CoA were investigated by routine MRI prior to catheterization. 3D whole-heart MRI was used to reconstruct geometries and 4D flow-sensitive phase-contrast MRI was used to acquire flows. Peak systolic flows were simulated using the program FLUENT.

RESULTS:

Peak systolic pressure drops in CoA measured by catheterization and CFD correlated significantly for both pre- and posttreatment measurements (pre r = 0.98, p = 0.00; post r = 0.87, p = 0.00). The pretreatment bias was -0.5 ± 3.33 mmHg (95% confidence interval -2.55 to 1.47 mmHg). CFD predicted a reduction of the peak systolic pressure drop after treatment that ranged from 17.6 ± 5.56 mmHg to 6.7 ± 5.58 mmHg. The posttreatment bias was 3.0 ± 2.91 mmHg (95% CI -1.74 to 5.43 mmHg).

CONCLUSION:

Peak systolic pressure drops can be reliably calculated using MRI-based CFD in a clinical setting. Therefore, CFD might be an attractive noninvasive alternative to diagnostic catheterization.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Coartação Aórtica / Velocidade do Fluxo Sanguíneo / Pressão Sanguínea / Angiografia por Ressonância Magnética / Modelos Cardiovasculares Tipo de estudo: Diagnostic_studies / Prognostic_studies / Risk_factors_studies Limite: Adolescent / Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Coartação Aórtica / Velocidade do Fluxo Sanguíneo / Pressão Sanguínea / Angiografia por Ressonância Magnética / Modelos Cardiovasculares Tipo de estudo: Diagnostic_studies / Prognostic_studies / Risk_factors_studies Limite: Adolescent / Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Alemanha