Your browser doesn't support javascript.
loading
Non-invasive respiratory monitoring using long-period fiber grating sensors.
Petrovic, M D; Petrovic, J; Danicic, A; Vukcevic, M; Bojovic, B; Hadzievski, Lj; Allsop, T; Lloyd, G; Webb, D J.
Afiliação
  • Petrovic MD; Vinca Institute of Nuclear Sciences,University of Belgrade, Mike Petrovica Alasa 12-14, 11000 Belgrade, Serbia.
  • Petrovic J; Vinca Institute of Nuclear Sciences,University of Belgrade, Mike Petrovica Alasa 12-14, 11000 Belgrade, Serbia.
  • Danicic A; Vinca Institute of Nuclear Sciences,University of Belgrade, Mike Petrovica Alasa 12-14, 11000 Belgrade, Serbia.
  • Vukcevic M; School of Medicine, University of Belgrade, Dr Subotica 8, 11000 Belgrade, Serbia.
  • Bojovic B; Vinca Institute of Nuclear Sciences,University of Belgrade, Mike Petrovica Alasa 12-14, 11000 Belgrade, Serbia.
  • Hadzievski Lj; Vinca Institute of Nuclear Sciences,University of Belgrade, Mike Petrovica Alasa 12-14, 11000 Belgrade, Serbia.
  • Allsop T; Aston Institute of Photonic Technologies, Aston Triangle, B4 7ET Birmingham, UK.
  • Lloyd G; Moog Insensys LTD, Ocean House, Whittle Avenue, Segensworth West, Fareham, P015 5SX, UK.
  • Webb DJ; Aston Institute of Photonic Technologies, Aston Triangle, B4 7ET Birmingham, UK.
Biomed Opt Express ; 5(4): 1136-44, 2014 Apr 01.
Article em En | MEDLINE | ID: mdl-24761295
ABSTRACT
In non-invasive ventilation, continuous monitoring of respiratory volumes is essential. Here, we present a method for the measurement of respiratory volumes by a single fiber-grating sensor of bending and provide the proof-of-principle by applying a calibration-test measurement procedure on a set of 18 healthy volunteers. Results establish a linear correlation between a change in lung volume and the corresponding change in a local thorax curvature. They also show good sensor accuracy in measurements of tidal and minute respiratory volumes for different types of breathing. The proposed technique does not rely on the air flow through an oronasal mask or the observation of chest movement by a clinician, which distinguishes it from the current clinical practice.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Clinical_trials Idioma: En Revista: Biomed Opt Express Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Clinical_trials Idioma: En Revista: Biomed Opt Express Ano de publicação: 2014 Tipo de documento: Article