Your browser doesn't support javascript.
loading
Evaluation of the broad-range PCR-electrospray ionization mass spectrometry (PCR/ESI-MS) system and virus microarrays for virus detection.
Taliaferro, Lanyn P; Galvin, Teresa A; Ma, Hailun; Shaheduzzaman, Syed; Williams, Dhanya K; Glasner, Dustin R; Khan, Arifa S.
Afiliação
  • Taliaferro LP; Laboratory of Retroviruses, Division of Viral Products, Center for Biologics Evaluation and Research, U.S. Food and Drug Administration, 8800 Rockville Pike, HFM-454, Bethesda, MD 20892, USA. lanyn.taliaferro@fda.hhs.gov.
  • Galvin TA; Laboratory of Retroviruses, Division of Viral Products, Center for Biologics Evaluation and Research, U.S. Food and Drug Administration, 8800 Rockville Pike, HFM-454, Bethesda, MD 20892, USA. teresa.galvin@fda.hhs.gov.
  • Ma H; Laboratory of Retroviruses, Division of Viral Products, Center for Biologics Evaluation and Research, U.S. Food and Drug Administration, 8800 Rockville Pike, HFM-454, Bethesda, MD 20892, USA. hailun.ma@fda.hhs.gov.
  • Shaheduzzaman S; Laboratory of Retroviruses, Division of Viral Products, Center for Biologics Evaluation and Research, U.S. Food and Drug Administration, 8800 Rockville Pike, HFM-454, Bethesda, MD 20892, USA. syed.shaheduzzaman@fda.hhs.gov.
  • Williams DK; Laboratory of Retroviruses, Division of Viral Products, Center for Biologics Evaluation and Research, U.S. Food and Drug Administration, 8800 Rockville Pike, HFM-454, Bethesda, MD 20892, USA. dhanya.williams@fda.hhs.gov.
  • Glasner DR; Laboratory of Retroviruses, Division of Viral Products, Center for Biologics Evaluation and Research, U.S. Food and Drug Administration, 8800 Rockville Pike, HFM-454, Bethesda, MD 20892, USA. drglasner@berkeley.edu.
  • Khan AS; Laboratory of Retroviruses, Division of Viral Products, Center for Biologics Evaluation and Research, U.S. Food and Drug Administration, 8800 Rockville Pike, HFM-454, Bethesda, MD 20892, USA. arifa.khan@fda.hhs.gov.
Viruses ; 6(5): 1876-96, 2014 Apr 25.
Article em En | MEDLINE | ID: mdl-24777034
ABSTRACT
Advanced nucleic acid-based technologies are powerful research tools for novel virus discovery but need to be standardized for broader applications such as virus detection in biological products and clinical samples. We have used well-characterized retrovirus stocks to evaluate the limit of detection (LOD) for broad-range PCR with electrospray ionization mass spectrometry (PCR/ESI-MS or PLEX-ID), RT-PCR assays, and virus microarrays. The results indicated that in the absence of background cellular nucleic acids, PLEX-ID and RT-PCR had a similar LOD for xenotropic murine retrovirus-related virus (XMRV; 3.12 particles per µL) whereas sensitivity of virus detection was 10-fold greater using virus microarrays. When virus was spiked into a background of cellular nucleic acids, the LOD using PLEX-ID remained the same, whereas virus detection by RT-PCR was 10-fold less sensitive, and no virus could be detected by microarrays. Expected endogenous retrovirus (ERV) sequences were detected in cell lines tested and known species-specific viral sequences were detected in bovine serum and porcine trypsin. A follow-up strategy was developed using PCR amplification, nucleotide sequencing, and bioinformatics to demonstrate that an RD114-like retrovirus sequence that was detected by PLEX-ID in canine cell lines (Madin-Darby canine kidney (MDCK) and Cf2Th canine thymus) was due to defective, endogenous gammaretrovirus-related sequences.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Virologia / Reação em Cadeia da Polimerase / Retrovirus Endógenos / Espectrometria de Massas por Ionização por Electrospray / Análise em Microsséries / Testes Diagnósticos de Rotina Tipo de estudo: Diagnostic_studies Limite: Animals / Humans Idioma: En Revista: Viruses Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Virologia / Reação em Cadeia da Polimerase / Retrovirus Endógenos / Espectrometria de Massas por Ionização por Electrospray / Análise em Microsséries / Testes Diagnósticos de Rotina Tipo de estudo: Diagnostic_studies Limite: Animals / Humans Idioma: En Revista: Viruses Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Estados Unidos