Your browser doesn't support javascript.
loading
Studying functional properties of hydrogel and silicone-hydrogel contact lenses with PALS, MIR and Raman spectroscopy.
Filipecki, J; Sitarz, M; Kocela, A; Kotynia, K; Jelen, P; Filipecka, K; Gaweda, M.
Afiliação
  • Filipecki J; Institute of Physics, Jan Dlugosz University, Al. Armii Krajowej 13/15, 42-200 Czestochowa, Poland. Electronic address: j.filipecki@ajd.czest.pl.
  • Sitarz M; AGH University of Science and Technology, Faculty of Materials Science and Ceramics, Al. Mickiewicza 30, 30-059 Cracow, Poland.
  • Kocela A; Institute of Physics, Jan Dlugosz University, Al. Armii Krajowej 13/15, 42-200 Czestochowa, Poland.
  • Kotynia K; AGH University of Science and Technology, Faculty of Materials Science and Ceramics, Al. Mickiewicza 30, 30-059 Cracow, Poland.
  • Jelen P; AGH University of Science and Technology, Faculty of Materials Science and Ceramics, Al. Mickiewicza 30, 30-059 Cracow, Poland.
  • Filipecka K; Institute of Physics, Czestochowa University of Technology, Al. Armii Krajowej 19, 42-200 Czestochowa, Poland.
  • Gaweda M; AGH University of Science and Technology, Faculty of Materials Science and Ceramics, Al. Mickiewicza 30, 30-059 Cracow, Poland.
Spectrochim Acta A Mol Biomol Spectrosc ; 131: 686-90, 2014 Oct 15.
Article em En | MEDLINE | ID: mdl-24929503
Determination of free volume holes of the hydrogel and silicone-hydrogel polymer contact lenses were investigated. Two types of polymer contact lenses were used as materials: the first is a hydrogel contact lenses Proclear family (Omafilcon A), while the second is a silicone-hydrogel contact lens of the family Biofinity (Comfilcon A). Positron annihilation lifetime spectroscopy PALS was used to characterize geometrical sizes and fraction of the free volume holes in the investigated samples. There is a clear difference in the free volume sizes and their fractions between silicone-hydrogel and polymer hydrogel contact lenses which in turn are connected with oxygen permeability in these lenses. Apart from that, spectroscopic (middle infrared) MIR and Raman examinations were carried out in order to demonstrate the differences of the water content in the test contact lenses.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Silicones / Lentes de Contato / Hidrogel de Polietilenoglicol-Dimetacrilato Idioma: En Revista: Spectrochim Acta A Mol Biomol Spectrosc Assunto da revista: BIOLOGIA MOLECULAR Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Silicones / Lentes de Contato / Hidrogel de Polietilenoglicol-Dimetacrilato Idioma: En Revista: Spectrochim Acta A Mol Biomol Spectrosc Assunto da revista: BIOLOGIA MOLECULAR Ano de publicação: 2014 Tipo de documento: Article