Sensitive fluorescence-based method for the rapid determination of polysorbate-80 content in therapeutic monoclonal antibody products.
Zheng, Songyan; Smith, Pedro; Burton, Lori; Adams, Monica L.
Afiliação
  • Zheng S; a Drug Product Science and Technology, Bristol-Myers Squibb , New Brunswick , NJ , USA.
  • Smith P; a Drug Product Science and Technology, Bristol-Myers Squibb , New Brunswick , NJ , USA.
  • Burton L; a Drug Product Science and Technology, Bristol-Myers Squibb , New Brunswick , NJ , USA.
  • Adams ML; a Drug Product Science and Technology, Bristol-Myers Squibb , New Brunswick , NJ , USA.
Pharm Dev Technol ; 20(7): 872-876, 2015 Nov.
Article em En | MEDLINE | ID: mdl-24946793
ABSTRACT
A sensitive and effective method has been developed for the rapid determination of polysorbate-80 content in therapeutic monoclonal antibody (mAb) products. The method is based on the detection of the fluorescence emission of 4,4'-dianilino-1,1'-binaphthyl-5,5'-disulfonic acid dipotassium salt (bis-ANS) enhanced by the presence of polysorbate-80. The developed method includes two approaches. One requires removal of the mAb from solution prior to analysis, while the other requires only simple sample dilution. The limits of detection and quantitation, calculated from the calibration curve generated in the absence of mAb-A, were 1.5 and 4.7 parts per million, respectively. Given the comparable linear range and linearity of the linear line between the solutions, with or without mAb, the limit of detection and quantitation is assumed to be similar. The dilution method is not only fast and simple in terms of sample preparation, but it is also particularly useful for analyzing the level of polysorbate-80 contained in highly concentrated mAb products. However, given that this method does require availability of polysorbate-80-free materials of mAb for preparation of calibration standards, the protein removal method may be useful for the cases where appropriate protein materials for standard preparation are limited or unavailable.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Guideline Idioma: En Revista: Pharm Dev Technol Assunto da revista: FARMACIA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Guideline Idioma: En Revista: Pharm Dev Technol Assunto da revista: FARMACIA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Estados Unidos