Your browser doesn't support javascript.
loading
Can we improve the early detection of atrial fibrillation in a stroke unit? Detection rate of a monitor with integrated detection software.
Arevalo-Manso, Juan Jose; Martínez-Sánchez, Patricia; Fuentes, Blanca; Ruiz-Ares, Gerardo; Sanz-Cuesta, Borja Enrique; Prefasi, Daniel; Juarez-Martin, Belén; Navarro-Parias, Azahara; Parrilla-Novo, Pilar; Diez-Tejedor, Exuperio.
Afiliação
  • Arevalo-Manso JJ; Department of Neurology and Stroke Centre, La Paz University Hospital; IdiPAZ, Hospital La Paz Institute for Health Research; Autonomous University of Madrid, Spain jjarevaloes@hotmail.com patrindalo@hotmail.com.
  • Martínez-Sánchez P; Department of Neurology and Stroke Centre, La Paz University Hospital; IdiPAZ, Hospital La Paz Institute for Health Research; Autonomous University of Madrid, Spain.
  • Fuentes B; Department of Neurology and Stroke Centre, La Paz University Hospital; IdiPAZ, Hospital La Paz Institute for Health Research; Autonomous University of Madrid, Spain.
  • Ruiz-Ares G; Department of Neurology and Stroke Centre, La Paz University Hospital; IdiPAZ, Hospital La Paz Institute for Health Research; Autonomous University of Madrid, Spain.
  • Sanz-Cuesta BE; Department of Neurology and Stroke Centre, La Paz University Hospital; IdiPAZ, Hospital La Paz Institute for Health Research; Autonomous University of Madrid, Spain.
  • Prefasi D; Department of Neurology and Stroke Centre, La Paz University Hospital; IdiPAZ, Hospital La Paz Institute for Health Research; Autonomous University of Madrid, Spain.
  • Juarez-Martin B; Department of Neurology and Stroke Centre, La Paz University Hospital; IdiPAZ, Hospital La Paz Institute for Health Research; Autonomous University of Madrid, Spain.
  • Navarro-Parias A; Department of Neurology and Stroke Centre, La Paz University Hospital; IdiPAZ, Hospital La Paz Institute for Health Research; Autonomous University of Madrid, Spain.
  • Parrilla-Novo P; Department of Neurology and Stroke Centre, La Paz University Hospital; IdiPAZ, Hospital La Paz Institute for Health Research; Autonomous University of Madrid, Spain.
  • Diez-Tejedor E; Department of Neurology and Stroke Centre, La Paz University Hospital; IdiPAZ, Hospital La Paz Institute for Health Research; Autonomous University of Madrid, Spain.
Eur J Cardiovasc Nurs ; 15(1): 64-71, 2016 Feb.
Article em En | MEDLINE | ID: mdl-25230856
ABSTRACT

INTRODUCTION:

It is unknown whether monitors that include atrial fibrillation recognition software (AF-RS) increase the rate of early atrial fibrillation (AF) detection in acute stroke. We aimed to evaluate the AF detection rate of an AF-RS monitor and compare it with standard monitoring.

METHODS:

This was a retrospective, single-centre observational study conducted on consecutive patients with acute transient ischaemic attack or brain infarction attended in a stroke unit (SU) with six beds. Five beds had a standard monitor with a three-lead electrocardiogram (ECG)-tracing monitor that did not automatically detect AF, and one bed had a 12-lead ECG monitor with integrated AF-RS. All patients were monitored for at least 24 h and underwent a daily ECG during their stay in the SU. In case of unknown stroke aetiology, the patients underwent 24 h Holter monitoring.

RESULTS:

A total of 76 patients were included 59 patients in the standard monitor group and 17 patients in the AF-RS monitor group. The mean age was 72.11 (±13.09) years, and 59.2% were men. A total of 20 new cases of AF were identified. The AF-RS monitor showed a higher rate of AF detection than the standard devices (57.1% vs 7.7%, p=0.031). The AF-RS monitor showed sensitivity, specificity, positive predictive value, and negative predictive values of 57.1%, 100%, 100% and 76.9%, respectively. For the standard monitors, these values were 7.7%, 100%, 100% and 79.3%, respectively.

CONCLUSION:

The monitor with AF-RS demonstrated a higher detection rate for AF than standard ECG monitoring in acute stroke patients in a SU.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Software / Ataque Isquêmico Transitório / Diagnóstico por Computador / Acidente Vascular Cerebral / Infarto Encefálico / Diagnóstico Precoce Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Eur J Cardiovasc Nurs Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / ENFERMAGEM Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Software / Ataque Isquêmico Transitório / Diagnóstico por Computador / Acidente Vascular Cerebral / Infarto Encefálico / Diagnóstico Precoce Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Eur J Cardiovasc Nurs Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / ENFERMAGEM Ano de publicação: 2016 Tipo de documento: Article