Your browser doesn't support javascript.
loading
Evaluating multiplexed quantitative phosphopeptide analysis on a hybrid quadrupole mass filter/linear ion trap/orbitrap mass spectrometer.
Erickson, Brian K; Jedrychowski, Mark P; McAlister, Graeme C; Everley, Robert A; Kunz, Ryan; Gygi, Steven P.
Afiliação
  • Erickson BK; Harvard Medical School , Department of Cell Biology, Boston, Massachusetts 02115, United States.
Anal Chem ; 87(2): 1241-9, 2015 Jan 20.
Article em En | MEDLINE | ID: mdl-25521595
ABSTRACT
As a driver for many biological processes, phosphorylation remains an area of intense research interest. Advances in multiplexed quantitation utilizing isobaric tags (e.g., TMT and iTRAQ) have the potential to create a new paradigm in quantitative proteomics. New instrumentation and software are propelling these multiplexed workflows forward, which results in more accurate, sensitive, and reproducible quantitation across tens of thousands of phosphopeptides. This study assesses the performance of multiplexed quantitative phosphoproteomics on the Orbitrap Fusion mass spectrometer. Utilizing a two-phosphoproteome model of precursor ion interference, we assessed the accuracy of phosphopeptide quantitation across a variety of experimental approaches. These methods included the use of synchronous precursor selection (SPS) to enhance TMT reporter ion intensity and accuracy. We found that (i) ratio distortion remained a problem for phosphopeptide analysis in multiplexed quantitative workflows, (ii) ratio distortion can be overcome by the use of an SPS-MS3 scan, (iii) interfering ions generally possessed a different charge state than the target precursor, and (iv) selecting only the phosphate neutral loss peak (single notch) for the MS3 scan still provided accurate ratio measurements. Remarkably, these data suggest that the underlying cause of interference may not be due to coeluting and cofragmented peptides but instead from consistent, low level background fragmentation. Finally, as a proof-of-concept 10-plex experiment, we compared phosphopeptide levels from five murine brains to five livers. In total, the SPS-MS3 method quantified 38 247 phosphopeptides, corresponding to 11 000 phosphorylation sites. With 10 measurements recorded for each phosphopeptide, this equates to more than 628 000 binary comparisons collected in less than 48 h.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fosfopeptídeos / Espectrometria de Massas / Química Encefálica / Cromatografia Líquida de Alta Pressão / Proteômica / Fígado Tipo de estudo: Evaluation_studies Limite: Animals Idioma: En Revista: Anal Chem Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fosfopeptídeos / Espectrometria de Massas / Química Encefálica / Cromatografia Líquida de Alta Pressão / Proteômica / Fígado Tipo de estudo: Evaluation_studies Limite: Animals Idioma: En Revista: Anal Chem Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Estados Unidos