Your browser doesn't support javascript.
loading
Diameter-related variations of geometrical, mechanical, and mass fraction data in the anterior portion of abdominal aortic aneurysms.
Tong, J; Cohnert, T; Holzapfel, G A.
Afiliação
  • Tong J; Graz University of Technology, Institute of Biomechanics, Kronesgasse 5-I, 8010, Graz, Austria; Shanghai East Hospital, Institute for Biomedical Engineering & Nano Science, Tongji University School of Medicine, Shanghai, PR China.
  • Cohnert T; Medical University of Graz, Clinical Department of Vascular Surgery, Graz, Austria.
  • Holzapfel GA; Graz University of Technology, Institute of Biomechanics, Kronesgasse 5-I, 8010, Graz, Austria. Electronic address: holzapfel@tugraz.at.
Eur J Vasc Endovasc Surg ; 49(3): 262-70, 2015 Mar.
Article em En | MEDLINE | ID: mdl-25617258
OBJECTIVE: Maximum aortic diameter is an important measure in rupture prediction of abdominal aortic aneurysms (AAAs). Analyzing the variations of geometrical, material, and biochemical properties with increased AAA diameters advances understanding of the effect of lesion enlargement on patient specific vascular properties. METHODS: 96 AAA samples were harvested during open surgical aneurysm repair. Geometrical factors such as the maximum intraluminal thrombus (ILT) thickness, wall thickness, and AAA expansion rate were measured. Biaxial extension and peeling tests were performed to characterize the biaxial mechanical responses and to quantify the dissection properties of aneurysmal tissue. Mass fraction analysis quantified the dry weight percentages of elastin and collagen within the AAA wall. Linear regression models were used to correlate geometrical, mechanical, and mass fraction data with maximum AAA diameter. RESULTS: Both ILT thickness and AAA expansion rate increased and were positively correlated with maximum AAA diameter, while there was a slight increase in wall thickness for AAAs with a larger maximum diameter. For the biaxial mechanical responses, mean peak stretches and maximum tangential moduli in the circumferential and longitudinal axes did not correlate with maximum AAA diameters. However, the quantified energy to propagate tissue dissections within intima-media composites showed a significant inverse correlation with maximum AAA diameter. Elastin content decreased significantly with increasing AAA diameter. CONCLUSION: Larger AAA diameters are associated with thicker ILTs, higher AAA expansion rates, and pronounced elastin loss, and may also lead to a higher propensity for tissue dissection and aneurysm rupture.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aorta Abdominal / Aneurisma da Aorta Abdominal / Hemodinâmica Tipo de estudo: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Eur J Vasc Endovasc Surg Assunto da revista: ANGIOLOGIA Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aorta Abdominal / Aneurisma da Aorta Abdominal / Hemodinâmica Tipo de estudo: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Eur J Vasc Endovasc Surg Assunto da revista: ANGIOLOGIA Ano de publicação: 2015 Tipo de documento: Article