Your browser doesn't support javascript.
loading
Measurement of Radiation Exposure When Using the Mini C-Arm to Reduce Pediatric Upper Extremity Fractures.
Sumko, Michael J; Hennrikus, William; Slough, Jennifer; Jensen, Kelly; Armstrong, Douglas; King, Stephen; Urish, Kenneth.
Afiliação
  • Sumko MJ; Penn State College of Medicine, Hershey, PA.
J Pediatr Orthop ; 36(2): 122-5, 2016 Mar.
Article em En | MEDLINE | ID: mdl-25730377
ABSTRACT

BACKGROUND:

Previous literature has underreported radiation exposure with the use of mini C-arm during pediatric forearm fracture reductions. The purpose of this study is to report an accurate amount of radiation exposure during fracture reductions using a mini C-arm that records the amount of kilovolts, milliamps, and the number of seconds of foot pedal use.

METHODS:

Eighty-six consecutive pediatric patients undergoing upper extremity fracture reduction in the emergency department were studied. The orthopaedic resident, either a PGY2 or PGY3, performed a manipulative reduction and casting of the fracture with use of the mini C-arm. Postreduction, in cast, anteroposterior and lateral images from the mini C-arm were saved to the computerized radiology system. The mini C-arm recorded the amount of kilovolts, milliamps, and the number of seconds that the foot pedal was used for each reduction. A radiology physicist (S.K.) calculated the amount of millirem (mR) exposure for each reduction from these data.

RESULTS:

The resident using the mini C-arm and the fracture pattern affected the amount of radiation exposure. The average mini C-arm mR exposure for distal radius fractures was 63 mR; forearm 109 mR; elbow 53 mR; and hand 69 mR. For comparison, conventional anteroposterior/lateral forearm radiographs emit an average of 20 mR. Less-experienced PGY2 residents had a higher mR exposure per reduction compared with PGY3 residents.

CONCLUSIONS:

Radiation exposure when using the mini C-arm for reduction of pediatric fractures has been underestimated in previous literature. Radiation from the mini C-arm exceeded that from conventional radiographs in most cases. We recommend that residents receive training about the use of the mini C-arm before its utilization as an aid to reduce pediatric fractures in the emergency department.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Exposição à Radiação / Extremidade Superior / Fraturas Ósseas / Manipulação Ortopédica Limite: Adolescent / Child / Child, preschool / Female / Humans / Infant / Male Idioma: En Revista: J Pediatr Orthop Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Panamá

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Exposição à Radiação / Extremidade Superior / Fraturas Ósseas / Manipulação Ortopédica Limite: Adolescent / Child / Child, preschool / Female / Humans / Infant / Male Idioma: En Revista: J Pediatr Orthop Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Panamá