Your browser doesn't support javascript.
loading
Comparison between radiofrequency with contact force-sensing and second-generation cryoballoon for paroxysmal atrial fibrillation catheter ablation: a multicentre European evaluation.
Squara, Fabien; Zhao, Alexandre; Marijon, Eloi; Latcu, Decebal Gabriel; Providencia, Rui; Di Giovanni, Giacomo; Jauvert, Gaël; Jourda, Francois; Chierchia, Gian-Battista; De Asmundis, Carlo; Ciconte, Giuseppe; Alonso, Christine; Grimard, Caroline; Boveda, Serge; Cauchemez, Bruno; Saoudi, Nadir; Brugada, Pedro; Albenque, Jean-Paul; Thomas, Olivier.
Afiliação
  • Squara F; Cardiology Department, Pasteur University Hospital, 30 Voie romaine, 06000 Nice, France Clinique Ambroise Paré, Neuilly, France fabiensquara@gmail.com.
  • Zhao A; Clinique Ambroise Paré, Neuilly, France.
  • Marijon E; Clinique Pasteur, Toulouse, France Cardiology Department, European Georges Pompidou Hospital, Paris, France.
  • Latcu DG; Service de Cardiologie, Centre Hospitalier Princesse Grace, Monaco.
  • Providencia R; Clinique Pasteur, Toulouse, France.
  • Di Giovanni G; Heart Rhythm Management Centre, UZ Brussel-VUB, Brussels, Belgium.
  • Jauvert G; Clinique Ambroise Paré, Neuilly, France.
  • Jourda F; Clinique Pasteur, Toulouse, France.
  • Chierchia GB; Heart Rhythm Management Centre, UZ Brussel-VUB, Brussels, Belgium.
  • De Asmundis C; Heart Rhythm Management Centre, UZ Brussel-VUB, Brussels, Belgium.
  • Ciconte G; Heart Rhythm Management Centre, UZ Brussel-VUB, Brussels, Belgium.
  • Alonso C; Clinique Ambroise Paré, Neuilly, France.
  • Grimard C; Clinique Ambroise Paré, Neuilly, France.
  • Boveda S; Clinique Pasteur, Toulouse, France.
  • Cauchemez B; Clinique Ambroise Paré, Neuilly, France.
  • Saoudi N; Service de Cardiologie, Centre Hospitalier Princesse Grace, Monaco.
  • Brugada P; Heart Rhythm Management Centre, UZ Brussel-VUB, Brussels, Belgium.
  • Albenque JP; Clinique Pasteur, Toulouse, France.
  • Thomas O; Clinique Ambroise Paré, Neuilly, France.
Europace ; 17(5): 718-24, 2015 May.
Article em En | MEDLINE | ID: mdl-25840289
ABSTRACT

AIMS:

Whether pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) using contact force (CF)-guided radiofrequency (RF) or second-generation cryoballoon (CB) present similar efficacy and safety remains uncertain. METHODS AND

RESULTS:

We performed a multicentre study comparing procedural safety and arrhythmia recurrence after standardized PVI catheter ablation for PAF using CF-guided RF ablation (Thermocool(®) SmartTouch™, Biosense Webster; or Tacticath™, St Jude Medical) (CF group) with second-generation CB ablation (Arctic Front Advance™, Medtronic) (CB group). Overall, 376 patients (mean age 59.8 ± 10.4 years, 280 males) were enrolled in 4 centres 198 in CF group and 178 in CB group. Procedure was shorter for CB group than for CF group (109.6 ± 40 vs. 122.5 ± 40.7 min, P = 0.003), but fluoroscopy duration and X-ray exposure were not statistically different (P = 0.1 and P = 0.22, respectively). Overall complication rate was similar in both groups 14 (7.1%) in the CF group vs. 13 (7.3%) in the CB group (P = 0.93). However, transient right phrenic nerve palsy occurred only in CB group (10 patients, 5.6%; P = 0.001 vs. CF group) and severe non-lethal complications (embolic event, tamponade, or oesophageal injury) occurred only in CF group (5 patients, 2.5%; P = 0.03 vs. CB group). No periprocedural death occurred in either group. Single-procedure freedom from any atrial arrhythmias at 18 months post-ablation was comparable in CF group and CB group (76 vs. 73.3%, respectively, log rank P = 0.63).

CONCLUSION:

Pulmonary vein isolation using CF-guided RF and second-generation CB leads to comparable single-procedure arrhythmia-free survival at up to 18 months with similar overall complication rate.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Veias Pulmonares / Fibrilação Atrial / Transdutores de Pressão / Ablação por Cateter / Criocirurgia / Cateteres Cardíacos Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Revista: Europace Assunto da revista: CARDIOLOGIA / FISIOLOGIA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Veias Pulmonares / Fibrilação Atrial / Transdutores de Pressão / Ablação por Cateter / Criocirurgia / Cateteres Cardíacos Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Revista: Europace Assunto da revista: CARDIOLOGIA / FISIOLOGIA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: França