Your browser doesn't support javascript.
loading
ViVaMBC: estimating viral sequence variation in complex populations from illumina deep-sequencing data using model-based clustering.
Verbist, Bie; Clement, Lieven; Reumers, Joke; Thys, Kim; Vapirev, Alexander; Talloen, Willem; Wetzels, Yves; Meys, Joris; Aerssens, Jeroen; Bijnens, Luc; Thas, Olivier.
Afiliação
  • Verbist B; Department of Mathematical Modeling, Statistics and Bioinformatics, Ghent University, Coupure Links 653, Gent, 9000, Belgium. Bie.Verbist@ugent.be.
  • Clement L; Department of Applied Mathematics, Informatics and Statistics, Ghent University, Krijgslaan 281 S9, Gent, 9000, Belgium. Lieven.Clement@ugent.be.
  • Reumers J; Janssen R&D, Janssen Pharmaceutical Companies of J&J, Turnhoutseweg 30, Beerse, 2340, Belgium. JReumers@its.jnj.com.
  • Thys K; Janssen R&D, Janssen Pharmaceutical Companies of J&J, Turnhoutseweg 30, Beerse, 2340, Belgium. KThys@its.jnj.com.
  • Vapirev A; Janssen R&D, Janssen Pharmaceutical Companies of J&J, Turnhoutseweg 30, Beerse, 2340, Belgium. avapirev@its.jnj.com.
  • Talloen W; ExaScience Life Lab, Kapeldreef 75, Leuven, 3001, Belgium. avapirev@its.jnj.com.
  • Wetzels Y; Janssen R&D, Janssen Pharmaceutical Companies of J&J, Turnhoutseweg 30, Beerse, 2340, Belgium. WTalloen@its.jnj.com.
  • Meys J; Janssen R&D, Janssen Pharmaceutical Companies of J&J, Turnhoutseweg 30, Beerse, 2340, Belgium. YWetzel@its.jnj.com.
  • Aerssens J; Department of Mathematical Modeling, Statistics and Bioinformatics, Ghent University, Coupure Links 653, Gent, 9000, Belgium. joris.Meys@Ugent.be.
  • Bijnens L; Janssen R&D, Janssen Pharmaceutical Companies of J&J, Turnhoutseweg 30, Beerse, 2340, Belgium. JAerssen@its.jnj.com.
  • Thas O; Janssen R&D, Janssen Pharmaceutical Companies of J&J, Turnhoutseweg 30, Beerse, 2340, Belgium. LBIJNENS@its.jnj.com.
BMC Bioinformatics ; 16: 59, 2015 Feb 22.
Article em En | MEDLINE | ID: mdl-25887734
ABSTRACT

BACKGROUND:

Deep-sequencing allows for an in-depth characterization of sequence variation in complex populations. However, technology associated errors may impede a powerful assessment of low-frequency mutations. Fortunately, base calls are complemented with quality scores which are derived from a quadruplet of intensities, one channel for each nucleotide type for Illumina sequencing. The highest intensity of the four channels determines the base that is called. Mismatch bases can often be corrected by the second best base, i.e. the base with the second highest intensity in the quadruplet. A virus variant model-based clustering method, ViVaMBC, is presented that explores quality scores and second best base calls for identifying and quantifying viral variants. ViVaMBC is optimized to call variants at the codon level (nucleotide triplets) which enables immediate biological interpretation of the variants with respect to their antiviral drug responses.

RESULTS:

Using mixtures of HCV plasmids we show that our method accurately estimates frequencies down to 0.5%. The estimates are unbiased when average coverages of 25,000 are reached. A comparison with the SNP-callers V-Phaser2, ShoRAH, and LoFreq shows that ViVaMBC has a superb sensitivity and specificity for variants with frequencies above 0.4%. Unlike the competitors, ViVaMBC reports a higher number of false-positive findings with frequencies below 0.4% which might partially originate from picking up artificial variants introduced by errors in the sample and library preparation step.

CONCLUSIONS:

ViVaMBC is the first method to call viral variants directly at the codon level. The strength of the approach lies in modeling the error probabilities based on the quality scores. Although the use of second best base calls appeared very promising in our data exploration phase, their utility was limited. They provided a slight increase in sensitivity, which however does not warrant the additional computational cost of running the offline base caller. Apparently a lot of information is already contained in the quality scores enabling the model based clustering procedure to adjust the majority of the sequencing errors. Overall the sensitivity of ViVaMBC is such that technical constraints like PCR errors start to form the bottleneck for low frequency variant detection.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Variação Genética / Algoritmos / Software / Hepatite C / Hepacivirus / Sequenciamento de Nucleotídeos em Larga Escala / Mutação Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: BMC Bioinformatics Assunto da revista: INFORMATICA MEDICA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Bélgica

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Variação Genética / Algoritmos / Software / Hepatite C / Hepacivirus / Sequenciamento de Nucleotídeos em Larga Escala / Mutação Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: BMC Bioinformatics Assunto da revista: INFORMATICA MEDICA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Bélgica