Use of a prototype radioprotection cabin in vascular neuroradiology: Dosimetry and ergonomics.
Guersen, Joel; Karmouche, Kaouthar; Moyon, Jean Baptiste; Osmond, Estelle; Poulin, Maxime; Gabrillargues, Jean; Jean, Betty; Chabert, Emmanuel; Dutheil, Frédéric; Cassagnes, Lucie; Boyer, Louis.
Afiliação
  • Guersen J; Pôle d'imagerie et de radiologie interventionnelle, CHU de Clermont-Ferrand, 63003 Clermont-Ferrand, France. Electronic address: jguersen@chu-clermontferrand.fr.
  • Karmouche K; Pôle d'imagerie et de radiologie interventionnelle, CHU de Clermont-Ferrand, 63003 Clermont-Ferrand, France.
  • Moyon JB; Pôle d'imagerie et de radiologie interventionnelle, CHU de Clermont-Ferrand, 63003 Clermont-Ferrand, France.
  • Osmond E; Pôle d'imagerie et de radiologie interventionnelle, CHU de Clermont-Ferrand, 63003 Clermont-Ferrand, France.
  • Poulin M; Pôle d'imagerie et de radiologie interventionnelle, CHU de Clermont-Ferrand, 63003 Clermont-Ferrand, France.
  • Gabrillargues J; Pôle d'imagerie et de radiologie interventionnelle, CHU de Clermont-Ferrand, 63003 Clermont-Ferrand, France; ISIT UMR 6284 CNRS, université d'Auvergne, Auvergne, France.
  • Jean B; Pôle d'imagerie et de radiologie interventionnelle, CHU de Clermont-Ferrand, 63003 Clermont-Ferrand, France; ISIT UMR 6284 CNRS, université d'Auvergne, Auvergne, France.
  • Chabert E; Pôle d'imagerie et de radiologie interventionnelle, CHU de Clermont-Ferrand, 63003 Clermont-Ferrand, France.
  • Dutheil F; Pôle d'imagerie et de radiologie interventionnelle, CHU de Clermont-Ferrand, 63003 Clermont-Ferrand, France.
  • Cassagnes L; Pôle d'imagerie et de radiologie interventionnelle, CHU de Clermont-Ferrand, 63003 Clermont-Ferrand, France; ISIT UMR 6284 CNRS, université d'Auvergne, Auvergne, France.
  • Boyer L; Pôle d'imagerie et de radiologie interventionnelle, CHU de Clermont-Ferrand, 63003 Clermont-Ferrand, France; ISIT UMR 6284 CNRS, université d'Auvergne, Auvergne, France.
J Neuroradiol ; 42(6): 326-31, 2015 Dec.
Article em En | MEDLINE | ID: mdl-26026192
ABSTRACT

OBJECTIVES:

The aim of this work was to compare the performance of a prototype radioprotection cabin in interventional neuroradiology, and to assess its suitability for routine use. MATERIALS AND

METHODS:

The radioprotection cabin was a prototype derived from the CATHPAX AF(®) model. Three operators carried out 21 procedures (19 brain arteriographies and 2 embolizations) using the radioprotection cabin and not wearing the usual lead individual protection equipment (IPE), and 17 procedures (16 brain arteriographies and 1 embolization) wearing the standard lead IPE (vest, skirt, thyroid shield and goggles), and not using the radioprotection cabin. In all cases, thermoluminescent dosimeters (TLDs) were positioned at head, trunk, pelvic region, and upper and lower limbs to measure the dose equivalent for Hp(0.07) or Hp(3) that they received, attenuated by either the cabin or the lead IPE. Parallel to these dosimetric measurements, the ergonomics of the protection cabin were appraised by each radiologist after each procedure. RESULTS AND

CONCLUSION:

The cabin procured an overall reduction of 74% of the dose received on the whole body with Hp(0.07)=0.04 mSv ± 0.01 (CL=95%) against Hp(0.07)=0.12 mSv ± 0.04 (CL=95%) for the IPE. Body protection with the cabin was near complete, and close to 100% for the regions not protected by the usual IPE (e.g. the head). We also showed that design weaknesses noted by the operators that hampered procedures (light reflections, reduced hand mobility, awkward access to radioscopy pedal) could be remedied by maker's improvements to the prototype and minor changes in work habits.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doses de Radiação / Proteção Radiológica / Teste de Materiais / Exposição Ocupacional Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: J Neuroradiol Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doses de Radiação / Proteção Radiológica / Teste de Materiais / Exposição Ocupacional Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: J Neuroradiol Ano de publicação: 2015 Tipo de documento: Article