  • Alshahrani ST; *Vitreoretinal Division, King Khaled Eye Specialist Hospital, Riyadh, Saudi Arabia; †Ophthalmology Division, King Fahad Specialist Hospital, Dammam, Saudi Arabia; ‡Unit of Macula, Department of Ophthalmology, University and Polytechnic Hospital La Fe, Valencia, Spain; and §Retina Division, Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, Maryland.
Retina ; 36(1): 131-6, 2016 Jan.
Article em En | MEDLINE | ID: mdl-26079477
ABSTRACT

PURPOSE:

To evaluate the safety and efficacy of intravitreal dexamethasone implant (Ozurdex) for treating refractory macular edema in retinal vascular diseases.

METHODS:

This is a retrospective consecutive series of 53 eyes with refractory macular edema secondary to central retinal vein occlusion (13 eyes), branch retinal vein occlusion (14 eyes), and diabetic macular edema (26 eyes) treated with a single 0.7 mg dexamethasone implant. Data were collected on best-corrected visual acuity, intraocular pressure, and central macular thickness preoperatively and at 1, 3, and 6 months postoperatively.

RESULTS:

Baseline best-corrected visual acuity was 20/160 and improved statistically significantly to 20/80 and 20/60 at 1 months and 3 months, respectively (P < 0.05, both postoperative visits), and 20/100 at 6 months (P > 0.05). The central macular thickness at baseline was 569.96 ± 178.11 µm, and it decreased statistically significantly to 305.81 ± 155.94 µm, 386 ± 210.79 µm, and 446.41 ± 221.21 µm at 1, 3 and 6 months, respectively (P < 0.05, all visits compared with baseline). Fourteen (26%) eyes developed high intraocular pressure after implantation and was successfully controlled with topical medications, and cataract progressed in 1 (1.8%) eye.

CONCLUSION:

The dexamethasone implant improved macular edema in refractory cases resulting in statistically significant improvements in best-corrected visual acuity and central macular thickness that remained stable to 3 months and 6 months, respectively.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Oclusão da Veia Retiniana / Dexametasona / Edema Macular / Retinopatia Diabética / Glucocorticoides Tipo de estudo: Etiology_studies / Observational_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Retina Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Oclusão da Veia Retiniana / Dexametasona / Edema Macular / Retinopatia Diabética / Glucocorticoides Tipo de estudo: Etiology_studies / Observational_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Retina Ano de publicação: 2016 Tipo de documento: Article