Your browser doesn't support javascript.
loading
Vascular Imaging With Ferumoxytol as a Contrast Agent.
Hope, Michael D; Hope, Thomas A; Zhu, Chengcheng; Faraji, Farshid; Haraldsson, Henrik; Ordovas, Karen G; Saloner, David.
Afiliação
  • Hope MD; 1 All authors: Department of Radiology, University of California, San Francisco, 505 Parnassus Ave, Box 0628, San Francisco, CA 94143-0628.
  • Hope TA; 1 All authors: Department of Radiology, University of California, San Francisco, 505 Parnassus Ave, Box 0628, San Francisco, CA 94143-0628.
  • Zhu C; 1 All authors: Department of Radiology, University of California, San Francisco, 505 Parnassus Ave, Box 0628, San Francisco, CA 94143-0628.
  • Faraji F; 1 All authors: Department of Radiology, University of California, San Francisco, 505 Parnassus Ave, Box 0628, San Francisco, CA 94143-0628.
  • Haraldsson H; 1 All authors: Department of Radiology, University of California, San Francisco, 505 Parnassus Ave, Box 0628, San Francisco, CA 94143-0628.
  • Ordovas KG; 1 All authors: Department of Radiology, University of California, San Francisco, 505 Parnassus Ave, Box 0628, San Francisco, CA 94143-0628.
  • Saloner D; 1 All authors: Department of Radiology, University of California, San Francisco, 505 Parnassus Ave, Box 0628, San Francisco, CA 94143-0628.
AJR Am J Roentgenol ; 205(3): W366-73, 2015 Sep.
Article em En | MEDLINE | ID: mdl-26102308
ABSTRACT

OBJECTIVE:

Ferumoxytol is increasingly reported as an alternative to gadolinium-based contrast agents for MR angiography (MRA), particularly for patients with renal failure. This article summarizes more than 3 years of clinical experience with ferumoxytol-enhanced MRA for a range of indications and anatomic regions.

CONCLUSION:

Ferumoxytol-enhanced MRA has many advantages including that it is safe for patients with renal failure and provides a lengthy plateau of vascular signal as a blood pool agent that allows longer navigated MRA sequences.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doenças Vasculares / Angiografia por Ressonância Magnética / Meios de Contraste / Óxido Ferroso-Férrico Tipo de estudo: Observational_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: AJR Am J Roentgenol Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doenças Vasculares / Angiografia por Ressonância Magnética / Meios de Contraste / Óxido Ferroso-Férrico Tipo de estudo: Observational_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: AJR Am J Roentgenol Ano de publicação: 2015 Tipo de documento: Article