Placental elastography in a murine intrauterine growth restriction model.
Quibel, T; Deloison, B; Chammings, F; Chalouhi, G E; Siauve, N; Alison, M; Bessières, B; Gennisson, J L; Clément, O; Salomon, L J.
Afiliação
  • Quibel T; Departments of Obstetrics and Gynecology, CHI Poissy Saint Germain, 10 rue Champ, Gaillard, Poissy, BP 3082, France.
  • Deloison B; INSERM UMR 970, PARCC, Paris, France.
  • Chammings F; EA FETUS 7328, Université Paris Descartes, Paris, France.
  • Chalouhi GE; INSERM UMR 970, PARCC, Paris, France.
  • Siauve N; EA FETUS 7328, Université Paris Descartes, Paris, France.
  • Alison M; Maternité Necker-Enfants Malade, Assistance Publique Hopitaux de Paris, Faculté de Médecine, Univeristé Paris Descartes, Paris, France.
  • Bessières B; INSERM UMR 970, PARCC, Paris, France.
  • Gennisson JL; INSERM UMR 970, PARCC, Paris, France.
  • Clément O; Maternité Necker-Enfants Malade, Assistance Publique Hopitaux de Paris, Faculté de Médecine, Univeristé Paris Descartes, Paris, France.
  • Salomon LJ; INSERM UMR 970, PARCC, Paris, France.
Prenat Diagn ; 35(11): 1106-11, 2015 Nov.
Article em En | MEDLINE | ID: mdl-26193351
ABSTRACT

OBJECTIVE:

To compare placental elasticity in normal versus intrauterine growth restriction (IUGR) murine pregnancies using shear wave elastography (SWE).

METHODS:

Intrauterine growth restriction was created by ligation of the left uterine artery of Sprague-Dawley rats on E17. Ultrasonography (US) and elastography were performed 2 days later on exteriorized horns after laparotomy. Biparietal diameter (BPD) and abdominal diameter (AD) were measured and compared in each horn. Placental elasticity of each placenta was compared in the right and left horns, respectively, using the Young's modulus, which increases with increasing stiffness of the tissue.

RESULTS:

Two hundred seventeen feto-placental units from 18 rats were included. Fetuses in the left ligated horn had smaller biometric measurements than those in the right horn (6.7 vs 7.2 mm, p < 0.001, and 9.2 vs 11.2 mm, p < 0.001 for BPD and AD, respectively). Mean fetal weight was lower in the pups from the left than the right horn (1.65 vs 2.11 g; p < 0.001). Mean (SD) Young's modulus was higher for placentas from the left than the right horn (11.7 ± 1.5 kPa vs 8.01 ± 3.8 kPa, respectively; p < 0.001), indicating increased stiffness in placentas from the left than the right horn. There was an inverse relationship between fetal weight and placental elasticity (r = 0.42; p < 0.001).

CONCLUSION:

Shear wave elastography may be used to provide quantitative elasticity measurements of the placenta. In our model, placentas from IUGR fetuses demonstrated greater stiffness, which correlated with the degree of fetal growth restriction.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Placenta / Módulo de Elasticidade / Retardo do Crescimento Fetal Tipo de estudo: Diagnostic_studies Limite: Animals / Pregnancy Idioma: En Revista: Prenat Diagn Ano de publicação: 2015 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Placenta / Módulo de Elasticidade / Retardo do Crescimento Fetal Tipo de estudo: Diagnostic_studies Limite: Animals / Pregnancy Idioma: En Revista: Prenat Diagn Ano de publicação: 2015 Tipo de documento: Article País de afiliação: França