Development and validation of an HPLC-MS/MS analytical method for quantitative analysis of TCBA-TPQ, a novel anticancer makaluvamine analog, and application in a pharmacokinetic study in rats.
Chin J Nat Med
; 13(7): 554-60, 2015 Jul.
Article
em En
| MEDLINE
| ID: mdl-26233847
We have recently designed and synthesized several novel iminoquinone anticancer agents that have entered preclinical development for the treatment of human cancers. Herein we developed and validated a quantitative HPLC-MS/MS analytical method for one of the lead novel anticancer makaluvamine analog, TCBA-TPQ, and conducted a pharmacokinetic study in laboratory rats. Our results indicated that the HPLC-MS/MS method was precise, accurate, and specific. Using this method, we carried out in vitro and in vivo evaluations of the pharmacological properties of TCBA-TPQ and plasma pharmacokinetics in rats. Our results provide a basis for future preclinical and clinical development of this promising anticancer marine analog.