Left Ventricular Lead Placement Targeted at the Latest Activated Site Guided by Electrophysiological Mapping in Coronary Sinus Branches Improves Response to Cardiac Resynchronization Therapy.
Liang, Yanchun; Yu, Haibo; Zhou, Weiwei; Xu, Guoqing; Sun, Y I; Liu, Rong; Wang, Zulu; Han, Yaling.
Afiliação
  • Liang Y; Department of Cardiology, General Hospital of Shenyang Military Region, Shenyang, China.
  • Yu H; Department of Cardiology, General Hospital of Shenyang Military Region, Shenyang, China.
  • Zhou W; Department of Cardiology, General Hospital of Shenyang Military Region, Shenyang, China.
  • Xu G; Department of Cardiology, General Hospital of Shenyang Military Region, Shenyang, China.
  • Sun YI; Department of Cardiology, General Hospital of Shenyang Military Region, Shenyang, China.
  • Liu R; Department of Cardiology, General Hospital of Shenyang Military Region, Shenyang, China.
  • Wang Z; Department of Cardiology, General Hospital of Shenyang Military Region, Shenyang, China.
  • Han Y; Department of Cardiology, General Hospital of Shenyang Military Region, Shenyang, China.
J Cardiovasc Electrophysiol ; 26(12): 1333-9, 2015 Dec.
Article em En | MEDLINE | ID: mdl-26249040
ABSTRACT

INTRODUCTION:

Electrophysiological mapping (EPM) in coronary sinus (CS) branches is feasible for guiding LV lead placement to the optimal, latest activated site at cardiac resynchronization therapy (CRT) procedures. However, whether this procedure optimizes the response to CRT has not been demonstrated. This study was to evaluate effects of targeting LV lead at the latest activated site guided by EPM during CRT.

METHODS:

Seventy-six consecutive patients with advanced heart failure who were referred for CRT were divided into mapping (MG) and control groups (CG). In MG, the LV lead, also used as a mapping bipolar electrode, was placed at the latest activated site determined by EPM in CS branches. In CG, conventional CRT procedure was performed. Patients were followed for 6 months after CRT.

RESULTS:

Baseline characteristics were comparable between the 2 groups. In MG (n = 29), EPM was successfully performed in 85 of 91 CS branches during CRT. A LV lead was successfully placed at the latest activated site guided by EPM in 27 (93.1%) patients. Compared with CG (n = 47), MG had a significantly higher rate (86.2% vs. 63.8%, P = 0.039) of response (>15% reduction in LV end-systolic volume) to CRT, a higher percentage of patients with clinical improvement of ≥2 NYHA functional classes (72.4% vs. 44.7%, P = 0.032), and a shorter QRS duration (P = 0.004).

CONCLUSIONS:

LV lead placed at the latest activated site guided by EPM resulted in a significantly greater CRT response, and a shorter QRS duration.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Seio Coronário / Terapia de Ressincronização Cardíaca / Dispositivos de Terapia de Ressincronização Cardíaca / Insuficiência Cardíaca / Ventrículos do Coração Tipo de estudo: Observational_studies / Prognostic_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Cardiovasc Electrophysiol Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / FISIOLOGIA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Seio Coronário / Terapia de Ressincronização Cardíaca / Dispositivos de Terapia de Ressincronização Cardíaca / Insuficiência Cardíaca / Ventrículos do Coração Tipo de estudo: Observational_studies / Prognostic_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Cardiovasc Electrophysiol Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / FISIOLOGIA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: China