Your browser doesn't support javascript.
loading
Development of a Efficient and Sensitive Dispersive Liquid-Liquid Microextraction Technique for Extraction and Preconcentration of 10 ß2-Agonists in Animal Urine.
Li, Yang; Zhang, Wei; Wang, Rui-Guo; Wang, Pei-Long; Su, Xiao-Ou.
Afiliação
  • Li Y; Institute of Quality Standard & Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing, China.
  • Zhang W; Institute of Quality Standard & Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing, China.
  • Wang RG; Institute of Quality Standard & Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing, China.
  • Wang PL; Institute of Quality Standard & Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing, China.
  • Su XO; Institute of Quality Standard & Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing, China.
PLoS One ; 10(9): e0137194, 2015.
Article em En | MEDLINE | ID: mdl-26348922
Dispersive liquid-liquid microextraction (DLLME) coupled with ultra-performance liquid chromatography with tandem mass spectrometry (UPLC-MS/MS) was developed for the extraction and determination of 10 ß2-agonists in animal urine. Some experimental parameters, such as the type and volume of the extraction solvent, the concentration of the dispersant, the salt concentration, the pH value of the sample solution, the extraction time and the speed of centrifugation, were investigated and optimized. Under the optimized conditions, a good enrichment factors (4.8 to 32.3) were obtained for the extraction. The enrichment factor show that the concentration rate of DLLME is significantly higher than other pretreatment methods, and the detection sensitivity has been greatly improved. The calibration curves were linear, the correlation coefficient ranged from 0.9928 to 0.9999 for the concentration range of 0.05 to 50 ng mL(-1) and 0.1 to 50 ng mL(-1), and the relative standard deviations (RSDs, n = 15, intra and inter-day precision) at a concentration of 5 ng mL(-1) were in the range of 1.8 to 14.6%. The limits of detection (LODs) for the 10 ß2-agonists, based on a signal-to-noise ratio (S/N) of 3, were in the range of 0.01 to 0.03 ng mL(-1). The proposed method was used to identify ß2-agonists in three types of animal urine (swine, cattle, sheep), and the relative recoveries from each matrix were in the range of 89.2 to 106.8%, 90.0 to 109.8% and 89.2 to 107.2%, respectively.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Centrifugação / Espectrometria de Massas em Tandem / Agonistas de Receptores Adrenérgicos beta 2 / Microextração em Fase Líquida Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Revista: PLoS One Assunto da revista: CIENCIA / MEDICINA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Centrifugação / Espectrometria de Massas em Tandem / Agonistas de Receptores Adrenérgicos beta 2 / Microextração em Fase Líquida Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Revista: PLoS One Assunto da revista: CIENCIA / MEDICINA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: China