Your browser doesn't support javascript.
loading
ETHERNES: A new design of radionuclide source-based thermal neutron facility with large homogeneity area.
Bedogni, R; Sacco, D; Gómez-Ros, J M; Lorenzoli, M; Gentile, A; Buonomo, B; Pola, A; Introini, M V; Bortot, D; Domingo, C.
Afiliação
  • Bedogni R; INFN-LNF, via E. Fermi n. 40, 00044 Frascati (Roma), Italy. Electronic address: roberto.bedogni@lnf.infn.it.
  • Sacco D; INFN-LNF, via E. Fermi n. 40, 00044 Frascati (Roma), Italy; INAIL-DPIA, Via di Fontana Candida n. 1, 00040 Monteporzio Catone, Italy.
  • Gómez-Ros JM; INFN-LNF, via E. Fermi n. 40, 00044 Frascati (Roma), Italy; CIEMAT, Av. Complutense 40, 28040 Madrid, Spain.
  • Lorenzoli M; INFN-LNF, via E. Fermi n. 40, 00044 Frascati (Roma), Italy.
  • Gentile A; INFN-LNF, via E. Fermi n. 40, 00044 Frascati (Roma), Italy.
  • Buonomo B; INFN-LNF, via E. Fermi n. 40, 00044 Frascati (Roma), Italy.
  • Pola A; Politecnico di Milano, Dipartimento di Energia, via La Masa 34, 20156 Milano, Italy; INFN-Milano, Via Celoria 16, 20133 Milano, Italy.
  • Introini MV; Politecnico di Milano, Dipartimento di Energia, via La Masa 34, 20156 Milano, Italy.
  • Bortot D; Politecnico di Milano, Dipartimento di Energia, via La Masa 34, 20156 Milano, Italy; INFN-Milano, Via Celoria 16, 20133 Milano, Italy.
  • Domingo C; GRRI, Departament de Fisica, Universitat Autónoma de Barcelona, E-08193 Bellaterra, Spain.
Appl Radiat Isot ; 107: 171-176, 2016 Jan.
Article em En | MEDLINE | ID: mdl-26516990
ABSTRACT
A new thermal neutron irradiation facility based on an (241)Am-Be source embedded in a polyethylene moderator has been designed, and is called ETHERNES (Extended THERmal NEutron Source). The facility shows a large irradiation cavity (45 cm × 45 cm square section, 63 cm in height), which is separated from the source by means of a polyethylene sphere acting as shadowing object. Taking advantage of multiple scattering of neutrons with the walls of this cavity, the moderation process is especially effective and allows obtaining useful thermal fluence rates from 550 to 800 cm(-2) s(-1) with a source having nominal emission rate 5.7×10(6) s(-1). Irradiation planes parallel to the cavity bottom have been identified. The fluence rate across a given plane is as uniform as 3% (or better) in a disk with 30 cm (or higher) diameter. In practice, the value of thermal fluence rate simply depends on the height from the cavity bottom. The thermal neutron spectral fraction ranges from 77% up to 89%, depending on the irradiation plane. The angular distribution of thermal neutrons is roughly isotropic, with a slight prevalence of directions from bottom to top of the cavity. The mentioned characteristics are expected to be attractive for the scientific community involved in neutron metrology, neutron dosimetry and neutron detector testing.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies / Risk_factors_studies Idioma: En Revista: Appl Radiat Isot Assunto da revista: MEDICINA NUCLEAR / SAUDE AMBIENTAL Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies / Risk_factors_studies Idioma: En Revista: Appl Radiat Isot Assunto da revista: MEDICINA NUCLEAR / SAUDE AMBIENTAL Ano de publicação: 2016 Tipo de documento: Article