Your browser doesn't support javascript.
loading
A New Method to Simultaneously Quantify the Antioxidants: Carotenes, Xanthophylls, and Vitamin A in Human Plasma.
Colmán-Martínez, Mariel; Martínez-Huélamo, Miriam; Miralles, Esther; Estruch, Ramón; Lamuela-Raventós, Rosa M.
Afiliação
  • Colmán-Martínez M; Nutrition and Food Science Department, XaRTA, INSA, Pharmacy School, University of Barcelona, Avenue Joan XXII s/n, 08028 Barcelona, Spain.
  • Martínez-Huélamo M; Nutrition and Food Science Department, XaRTA, INSA, Pharmacy School, University of Barcelona, Avenue Joan XXII s/n, 08028 Barcelona, Spain ; CIBER CB06/03 Fisiopatología de la Obesidad y la Nutrición, CIBEROBN, Choupana s/n, 15706 Santiago de Compostela, Spain.
  • Miralles E; Scientific and Technical Services, University of Barcelona, Baldiri Reixac, 10, 08028 Barcelona, Spain.
  • Estruch R; CIBER CB06/03 Fisiopatología de la Obesidad y la Nutrición, CIBEROBN, Choupana s/n, 15706 Santiago de Compostela, Spain ; Department of Internal Medicine, Hospital Clínic, IDIBAPS, University of Barcelona, Villarroel, 170, 08036 Barcelona, Spain.
  • Lamuela-Raventós RM; Nutrition and Food Science Department, XaRTA, INSA, Pharmacy School, University of Barcelona, Avenue Joan XXII s/n, 08028 Barcelona, Spain ; CIBER CB06/03 Fisiopatología de la Obesidad y la Nutrición, CIBEROBN, Choupana s/n, 15706 Santiago de Compostela, Spain.
Oxid Med Cell Longev ; 2015: 9268531, 2015.
Article em En | MEDLINE | ID: mdl-26697143
ABSTRACT
A simple and accurate reversed phase high-performance liquid chromatography coupled with diode array detector (HPLC-DAD) method for simultaneously determining and quantifying the antioxidants carotenes, xanthophylls, and retinol in human plasma is presented in this paper. Compounds were extracted with hexane, a C30 column, and a mobile phase of methanol, methyl tert-butyl ether, and water were used for the separation of the compounds. A total of 8 carotenoids, 3 Z-ß-carotene isomers, and 1 fat-soluble vitamin (retinol) were resolved within 72 min at a flow rate of 0.6 mL/min. Detection was achieved at 450 nm for carotenoids and 330 nm for retinol. To evaluate the effectiveness of themethod, it has been applied to an intervention study conducted on eight volunteers. Results. Limits of detection were between 0.1 µg/mL for lycopene and astaxanthin and 1.3 µg/mL for 15-Z-ß-carotene. Recoveries were ranged between 89% and 113% for α-carotene and astaxanthin, respectively. Accuracy was between 90.7% and 112.2% and precision was between 1% and 15% RSD. In human plasma samples compounds studied were identified besides three lycopene isomers, demonstrated to be suitable for application in dietary intervention studies. Conclusions. Due to its accuracy, precision, selectivity, and reproducibility, this method is suitable to dietary habits and/or antioxidants status studies.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vitamina A / Carotenoides / Xantofilas / Antioxidantes Limite: Humans Idioma: En Revista: Oxid Med Cell Longev Assunto da revista: METABOLISMO Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Espanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vitamina A / Carotenoides / Xantofilas / Antioxidantes Limite: Humans Idioma: En Revista: Oxid Med Cell Longev Assunto da revista: METABOLISMO Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Espanha