Your browser doesn't support javascript.
loading
Utilizing confocal laser endomicroscopy for evaluating the adequacy of laparoscopic liver ablation.
Schneider, Crispin; Johnson, Sean P; Walker-Samuel, Simon; Gurusamy, Kurinchi; Clarkson, Matthew J; Thompson, Stephen; Song, Yi; Totz, Johannes; Cook, Richard J; Desjardins, Adrien E; Hawkes, David J; Davidson, Brian R.
Afiliação
  • Schneider C; Division of Surgery and Interventional Science, Royal Free Campus, University College London, Pond Street, NW3 2QG, London, UK.
  • Johnson SP; Centre for Advanced Biomedical Imaging, Division of Medicine, University College London, London, United Kingdom.
  • Walker-Samuel S; Centre for Advanced Biomedical Imaging, Division of Medicine, University College London, London, United Kingdom.
  • Gurusamy K; Division of Surgery and Interventional Science, Royal Free Campus, University College London, Pond Street, NW3 2QG, London, UK.
  • Clarkson MJ; Division of Tissue Engineering and Biophotonics, Kings College London Dental Institute, London, United Kingdom.
  • Thompson S; Division of Tissue Engineering and Biophotonics, Kings College London Dental Institute, London, United Kingdom.
  • Song Y; Division of Tissue Engineering and Biophotonics, Kings College London Dental Institute, London, United Kingdom.
  • Totz J; Division of Tissue Engineering and Biophotonics, Kings College London Dental Institute, London, United Kingdom.
  • Cook RJ; Division of Tissue Engineering and Biophotonics, Kings College London Dental Institute, London, United Kingdom.
  • Desjardins AE; Department of Medical Physics and Bioengineering, University College London, London, United Kingdom.
  • Hawkes DJ; Centre for Medical Image Computing, University College London, London, United Kingdom.
  • Davidson BR; Division of Surgery and Interventional Science, Royal Free Campus, University College London, Pond Street, NW3 2QG, London, UK.
Lasers Surg Med ; 48(3): 299-310, 2016 Mar.
Article em En | MEDLINE | ID: mdl-26718623
ABSTRACT

BACKGROUND:

Laparoscopic liver ablation therapy can be used for the treatment of primary and secondary liver malignancy. The increased incidence of cancer recurrence associated with this approach, has been attributed to the inability of monitoring the extent of ablated liver tissue.

METHODS:

The feasibility of assessing liver ablation with probe-based confocal laser endomicroscopy (CLE) was studied in a porcine model of laparoscopic microwave liver ablation. Following the intravenous injection of the fluorophores fluorescein and indocyanine green, CLE images were recorded at 488 nm and 660 nm wavelength and compared to liver histology. Statistical analysis was performed to assess if fluorescence intensity change can predict the presence of ablated liver tissue.

RESULTS:

CLE imaging of fluorescein at 488 nm provided good visualization of the hepatic microvasculature; whereas, CLE imaging of indocyanine green at 660 nm enabled detailed visualization of hepatic sinusoid architecture and interlobular septations. Fluorescence intensity as measured in relative fluorescence units was found to be 75-100% lower in ablated compared to healthy liver regions. General linear mixed modeling and ROC analysis found the decrease in fluorescence to be statistically significant.

CONCLUSION:

Laparoscopic, dual wavelength CLE imaging using two different fluorophores enables clinically useful visualization of multiple liver tissue compartments, in greater detail than is possible at a single wavelength. CLE imaging may provide valuable intraoperative information on the extent of laparoscopic liver ablation.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas de Ablação / Hepatectomia / Fígado / Micro-Ondas Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Revista: Lasers Surg Med Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas de Ablação / Hepatectomia / Fígado / Micro-Ondas Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Revista: Lasers Surg Med Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Reino Unido