Your browser doesn't support javascript.
loading
How Accurate is Your Sclerostin Measurement? Comparison Between Three Commercially Available Sclerostin ELISA Kits.
Piec, Isabelle; Washbourne, Christopher; Tang, Jonathan; Fisher, Emily; Greeves, Julie; Jackson, Sarah; Fraser, William D.
Afiliação
  • Piec I; Bioanalytical Facility, University of East Anglia, Floor 2, Bob Champion Research and Education Building, Norwich Research Park, James Watson Road, Norwich, NR4 7UQ, UK. i.piec@uea.ac.uk.
  • Washbourne C; Bioanalytical Facility, University of East Anglia, Floor 2, Bob Champion Research and Education Building, Norwich Research Park, James Watson Road, Norwich, NR4 7UQ, UK.
  • Tang J; Bioanalytical Facility, University of East Anglia, Floor 2, Bob Champion Research and Education Building, Norwich Research Park, James Watson Road, Norwich, NR4 7UQ, UK.
  • Fisher E; Bioanalytical Facility, University of East Anglia, Floor 2, Bob Champion Research and Education Building, Norwich Research Park, James Watson Road, Norwich, NR4 7UQ, UK.
  • Greeves J; Women Ground Close Combat Review, Directorate of Manning (Army), Blenheim Bld, IDL 27, Monxton Road, Andover, SP11 8HT, UK.
  • Jackson S; Women Ground Close Combat Review, Directorate of Manning (Army), Blenheim Bld, IDL 27, Monxton Road, Andover, SP11 8HT, UK.
  • Fraser WD; Bioanalytical Facility, University of East Anglia, Floor 2, Bob Champion Research and Education Building, Norwich Research Park, James Watson Road, Norwich, NR4 7UQ, UK.
Calcif Tissue Int ; 98(6): 546-55, 2016 Jun.
Article em En | MEDLINE | ID: mdl-26749312
ABSTRACT
Sclerostin, bone formation antagonist is in the spotlight as a potential biomarker for diseases presenting with associated bone disorders such as chronic kidney disease (CDK-MBD). Accurate measurement of sclerostin is therefore important. Several immunoassays are available to measure sclerostin in serum and plasma. We compared the performance of three commercial ELISA kits. We measured sclerostin concentrations in serum and EDTA plasma obtained from healthy young (18-26 years) human subjects using kits from Biomedica, TECOmedical and from R&D Systems. The circulating sclerostin concentrations were systematically higher when measured with the Biomedica assay (serum 35.5 ± 1.1 pmol/L; EDTA 39.4 ± 2.0 pmol/L; mean ± SD) as compared with TECOmedical (serum 21.8 ± 0.7 pmol/L; EDTA 27.2 ± 1.3 pmol/L) and R&D Systems (serum 7.6 ± 0.3 pmol/L; EDTA 30.9 ± 1.5 pmol/L). We found a good correlation between the assay for EDTA plasma (r > 0.6; p < 0.001) while in serum, only measurements obtained using TECOmedical and R&D Systems assays correlated significantly (r = 0.78; p < 0.001). There was no correlation between matrices results when using the Biomedica kit (r = 0.20). The variability in values generated from Biomedica, R&D Systems and TECOmedical assays raises questions regarding the accuracy and specificity of the assays. Direct comparison of studies using different kits is not possible and great care should be given to measurement of sclerostin, with traceability of reagents. Standardization with appropriate material is required before different sclerostin assays can be introduced in clinical practice.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Kit de Reagentes para Diagnóstico / Ensaio de Imunoadsorção Enzimática / Biomarcadores / Proteínas Morfogenéticas Ósseas Limite: Adolescent / Adult / Humans Idioma: En Revista: Calcif Tissue Int Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Kit de Reagentes para Diagnóstico / Ensaio de Imunoadsorção Enzimática / Biomarcadores / Proteínas Morfogenéticas Ósseas Limite: Adolescent / Adult / Humans Idioma: En Revista: Calcif Tissue Int Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Reino Unido