Your browser doesn't support javascript.
loading
Evaluation of a new transperineal ultrasound probe for inter-fraction image-guidance for definitive and post-operative prostate cancer radiotherapy.
Fargier-Voiron, Marie; Presles, Benoît; Pommier, Pascal; Munoz, Alexandre; Rit, Simon; Sarrut, David; Biston, Marie-Claude.
Afiliação
  • Fargier-Voiron M; CREATIS, INSA, Université de Lyon, CNRS UMR5220, Inserm U1044, Lyon F-69622, France.
  • Presles B; CREATIS, INSA, Université de Lyon, CNRS UMR5220, Inserm U1044, Lyon F-69622, France.
  • Pommier P; Léon Bérard Cancer Center, University of Lyon, Lyon F-69373, France.
  • Munoz A; Léon Bérard Cancer Center, University of Lyon, Lyon F-69373, France.
  • Rit S; CREATIS, INSA, Université de Lyon, CNRS UMR5220, Inserm U1044, Lyon F-69622, France.
  • Sarrut D; CREATIS, INSA, Université de Lyon, CNRS UMR5220, Inserm U1044, Lyon F-69622, France; Léon Bérard Cancer Center, University of Lyon, Lyon F-69373, France.
  • Biston MC; CREATIS, INSA, Université de Lyon, CNRS UMR5220, Inserm U1044, Lyon F-69622, France; Léon Bérard Cancer Center, University of Lyon, Lyon F-69373, France. Electronic address: marie-claude.biston@lyon.unicancer.fr.
Phys Med ; 32(3): 499-505, 2016 Mar.
Article em En | MEDLINE | ID: mdl-26851164
ABSTRACT

PURPOSE:

The aim of this study was to evaluate a new system based on transperineal ultrasound (TP-US) acquisitions for prostate and post-prostatectomy pre-treatment positioning by comparing this device to cone-beam computed tomography (CBCT).

METHODS:

The differences between CBCT/CT and TP-US/TP-US registrations were analyzed on 427 and 453 sessions for 13 prostate and 14 post-prostatectomy patients, respectively. The inter-operator variability (IOV) of the registration process, and the impact and variability of the probe pressure were also evaluated.

RESULTS:

CBCT and TP-US shift agreements at ± 5 mm were 76.6%, 95.1%, 96.3% and 90.3%, 85.0%, 97.6% in anterior-posterior, superior-inferior and left-right directions, for prostate and post-prostatectomy patients, respectively. IOV values were similar between the 2 modalities. Displacements above 5 mm due to strong pressures were observed on both localizations, but such pressures were rarely reproduced during treatment courses.

CONCLUSIONS:

High concordance between CBCT/CT and TP-US/TP-US localization of prostates or prostatic beds was found in this study. TP-US based prepositioning is a feasible method to ensure accurate treatment delivery, and represents an attractive alternative to invasive and/or irradiating imaging modalities.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Próstata / Ultrassonografia de Intervenção Tipo de estudo: Etiology_studies / Guideline / Incidence_studies / Observational_studies / Risk_factors_studies Limite: Humans / Male Idioma: En Revista: Phys Med Assunto da revista: BIOFISICA / BIOLOGIA / MEDICINA Ano de publicação: 2016 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Próstata / Ultrassonografia de Intervenção Tipo de estudo: Etiology_studies / Guideline / Incidence_studies / Observational_studies / Risk_factors_studies Limite: Humans / Male Idioma: En Revista: Phys Med Assunto da revista: BIOFISICA / BIOLOGIA / MEDICINA Ano de publicação: 2016 Tipo de documento: Article País de afiliação: França