Your browser doesn't support javascript.
loading
Contrast volume reduction using third generation dual source computed tomography for the evaluation of patients prior to transcatheter aortic valve implantation.
Bittner, Daniel O; Arnold, Martin; Klinghammer, Lutz; Schuhbaeck, Annika; Hell, Michaela M; Muschiol, Gerd; Gauss, Soeren; Lell, Michael; Uder, Michael; Hoffmann, Udo; Achenbach, Stephan; Marwan, Mohamed.
Afiliação
  • Bittner DO; Friedrich-Alexander University Erlangen-Nürnberg (FAU), Department of Internal Medicine 2 (Cardiology), University Hospital Erlangen, Ulmenweg 18, D-91054, Erlangen, Germany. daniel.bittner@uk-erlangen.de.
  • Arnold M; Cardiac MR PET CT Program, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA. daniel.bittner@uk-erlangen.de.
  • Klinghammer L; Friedrich-Alexander University Erlangen-Nürnberg (FAU), Department of Internal Medicine 2 (Cardiology), University Hospital Erlangen, Ulmenweg 18, D-91054, Erlangen, Germany.
  • Schuhbaeck A; Friedrich-Alexander University Erlangen-Nürnberg (FAU), Department of Internal Medicine 2 (Cardiology), University Hospital Erlangen, Ulmenweg 18, D-91054, Erlangen, Germany.
  • Hell MM; Friedrich-Alexander University Erlangen-Nürnberg (FAU), Department of Internal Medicine 2 (Cardiology), University Hospital Erlangen, Ulmenweg 18, D-91054, Erlangen, Germany.
  • Muschiol G; Friedrich-Alexander University Erlangen-Nürnberg (FAU), Department of Internal Medicine 2 (Cardiology), University Hospital Erlangen, Ulmenweg 18, D-91054, Erlangen, Germany.
  • Gauss S; Friedrich-Alexander University Erlangen-Nürnberg (FAU), Department of Internal Medicine 2 (Cardiology), University Hospital Erlangen, Ulmenweg 18, D-91054, Erlangen, Germany.
  • Lell M; Friedrich-Alexander University Erlangen-Nürnberg (FAU), Department of Internal Medicine 2 (Cardiology), University Hospital Erlangen, Ulmenweg 18, D-91054, Erlangen, Germany.
  • Uder M; Friedrich-Alexander University Erlangen-Nürnberg (FAU), Department of Radiology, University Hospital Erlangen, Erlangen, Germany.
  • Hoffmann U; Friedrich-Alexander University Erlangen-Nürnberg (FAU), Department of Radiology, University Hospital Erlangen, Erlangen, Germany.
  • Achenbach S; Cardiac MR PET CT Program, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
  • Marwan M; Friedrich-Alexander University Erlangen-Nürnberg (FAU), Department of Internal Medicine 2 (Cardiology), University Hospital Erlangen, Ulmenweg 18, D-91054, Erlangen, Germany.
Eur Radiol ; 26(12): 4497-4504, 2016 Dec.
Article em En | MEDLINE | ID: mdl-26995206
OBJECTIVES: Chronic renal failure is common in patients referred for transcatheter aortic valve implantation (TAVI). CT angiography is recommended and provides crucial information prior to TAVI. We evaluated the feasibility of a reduced contrast volume protocol for pre-procedural CT imaging. METHODS: Forty consecutive patients were examined with prospectively ECG-triggered high-pitch spiral acquisition using a novel third-generation dual-source CT system; 38 ml contrast agent was used. Image quality was graded on a visual scale (1-4). Contrast attenuation was measured at the level of the aortic root and at the iliac bifurcation. RESULTS: Mean patient age was 82 ± 6 years (23 males; 58 %). Mean attenuation/average image quality was 285 ± 60 HU/1.5 at the aortic annulus compared to 289 ± 74 HU/1.8 at the iliac bifurcation (p = 0.77/p = 0.29). Mean estimated effective radiation dose was 2.9 ± 0.3 mSv. A repeat acquisition was necessary in one patient due to image quality. Out of the 35 patients who underwent TAVI, 31 (89 %) patients had no or mild aortic regurgitation. Thirty-two (91 %) patients were discharged successfully. CONCLUSION: Pre-procedural CTA with a total of 38 ml contrast volume is feasible and clinically useful, using third-generation dual-source CT, allowing comprehensive imaging for procedural success. KEY POINTS: • Reduction of contrast agent volume is crucial in patients with chronic renal failure. • Novel third-generation computed tomography helps to reduce contrast agent volume. • Pre-procedural CT allows comprehensive imaging for procedural success before heart valve implantation. • A low-contrast CT protocol is feasible for pre-procedural TAVI planning.
Assuntos
Palavras-chave
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Tomografia Computadorizada por Raios X / Meios de Contraste / Substituição da Valva Aórtica Transcateter Tipo de estudo: Guideline / Observational_studies Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: Eur Radiol Assunto da revista: RADIOLOGIA Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Alemanha
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Tomografia Computadorizada por Raios X / Meios de Contraste / Substituição da Valva Aórtica Transcateter Tipo de estudo: Guideline / Observational_studies Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: Eur Radiol Assunto da revista: RADIOLOGIA Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Alemanha