Your browser doesn't support javascript.
loading
Competitive immunosensor based on gliadin immobilization on disposable carbon-nanogold screen-printed electrodes for rapid determination of celiotoxic prolamins.
Manfredi, Anita; Giannetto, Marco; Mattarozzi, Monica; Costantini, Monica; Mucchino, Claudio; Careri, Maria.
Afiliação
  • Manfredi A; Dipartimento di Chimica, Università degli Studi di Parma, Parco Area delle Scienze 17/A, 43124, Parma, Italy.
  • Giannetto M; Dipartimento di Chimica, Università degli Studi di Parma, Parco Area delle Scienze 17/A, 43124, Parma, Italy. marco.giannetto@unipr.it.
  • Mattarozzi M; Dipartimento di Chimica, Università degli Studi di Parma, Parco Area delle Scienze 17/A, 43124, Parma, Italy.
  • Costantini M; Dipartimento di Chimica, Università degli Studi di Parma, Parco Area delle Scienze 17/A, 43124, Parma, Italy.
  • Mucchino C; Dipartimento di Chimica, Università degli Studi di Parma, Parco Area delle Scienze 17/A, 43124, Parma, Italy.
  • Careri M; Dipartimento di Chimica, Università degli Studi di Parma, Parco Area delle Scienze 17/A, 43124, Parma, Italy.
Anal Bioanal Chem ; 408(26): 7289-98, 2016 Oct.
Article em En | MEDLINE | ID: mdl-27023219
ABSTRACT
The first competitive disposable amperometric immunosensor based on gliadin-functionalized carbon/nanogold screen-printed electrodes was developed for rapid determination of celiotoxic prolamins. To date, no competitive spectrophotometric or electrochemical immunoassays have yet been successfully applied to gluten detection in processed food samples, which require the use of complex prolamin extraction solutions containing additives with denaturing, reducing and disaggregating functions. Thus, in this work, great effort was put into the optimization and performance evaluation of the immunosensor in terms of suitability as a screening tool for analysis of cereal-based food samples. For this purpose, aqueous ethanol or complex extraction mixtures, as the patented Cocktail Solution®, were proved effective in the extraction of gliadin. Good sensitivity was achieved after optimization of the immunocompetitive assay, giving limit of detection and limit of quantitation of 8 and 22 ng/ml of gliadin, respectively, for ethanol extracts. The immunosensor was proved to be suitable also for samples extracted with Cocktail Solution® after a proper dilution. Analysis of real samples of different flours proved the suitability of the immunosensing device as a powerful tool for safety assessment of raw materials used for the formulation of dietary products for celiac disease patients. This immunosensor combines good analytical performance using a very simplified set-up protocol with suitability for rapid screening analysis performed using inexpensive and portable instrumentation. Graphical abstract Depiction of the development and working principle of the competitive immunosensor.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Grão Comestível / Análise de Alimentos / Gliadina Tipo de estudo: Etiology_studies / Evaluation_studies Limite: Humans Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Grão Comestível / Análise de Alimentos / Gliadina Tipo de estudo: Etiology_studies / Evaluation_studies Limite: Humans Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Itália