ABSTRACT
PURPOSE:
Prevention of multidrug resistant (MDR) bacterial contamination remains a major challenge in ICUs. Many hospital outbreaks involving MDR transmitted through environmental contamination have been reported. Bedside high-density EEG allow for dynamic cognitive evaluation in brain-injured patients and is used more and more frequently in clinical practice to evaluate brain function and predict outcome in severely neurologically impaired patients. Unfortunately, the material used for this procedure is not entirely disposable.METHOD:
We performed a systematic analysis of MDR bacterial contamination in patients contaminated in our ICU using specific bacteriological methods.RESULTS:
We report a proven case of cross-contamination of an extended-spectrum beta-lactamase (ESBL)-producing Klebsiella pneumoniae strain, and a possible case of cross-contamination of a carbapenem-resistant Acinetobacter baumannii strain.CONCLUSION:
Cross-contamination of MDR bacteria is possible through high-density EEG material. However, appropriate procedures can decrease this risk.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Infecções Bacterianas
/
Resistência Microbiana a Medicamentos
/
Eletroencefalografia
/
Unidades de Terapia Intensiva
Tipo de estudo:
Prognostic_studies
Limite:
Adult
/
Aged
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
Seizure
Assunto da revista:
NEUROLOGIA
Ano de publicação:
2016
Tipo de documento:
Article