Your browser doesn't support javascript.
loading
Enzymatically enhanced collisions on ultramicroelectrodes for specific and rapid detection of individual viruses.
Dick, Jeffrey E; Hilterbrand, Adam T; Strawsine, Lauren M; Upton, Jason W; Bard, Allen J.
Afiliação
  • Dick JE; Center for Electrochemistry, Department of Chemistry, The University of Texas at Austin, Austin, TX 78712;
  • Hilterbrand AT; Department of Molecular Biosciences, LaMontagne Center for Infectious Disease, and Institute for Cellular and Molecular Biology, The University of Texas at Austin, Austin, TX 78712.
  • Strawsine LM; Center for Electrochemistry, Department of Chemistry, The University of Texas at Austin, Austin, TX 78712;
  • Upton JW; Department of Molecular Biosciences, LaMontagne Center for Infectious Disease, and Institute for Cellular and Molecular Biology, The University of Texas at Austin, Austin, TX 78712.
  • Bard AJ; Center for Electrochemistry, Department of Chemistry, The University of Texas at Austin, Austin, TX 78712; ajbard@cm.utexas.edu.
Proc Natl Acad Sci U S A ; 113(23): 6403-8, 2016 Jun 07.
Article em En | MEDLINE | ID: mdl-27217569
ABSTRACT
We report the specific collision of a single murine cytomegalovirus (MCMV) on a platinum ultramicroelectrode (UME, radius of 1 µm). Antibody directed against the viral surface protein glycoprotein B functionalized with glucose oxidase (GOx) allowed for specific detection of the virus in solution and a biological sample (urine). The oxidation of ferrocene methanol to ferrocenium methanol was carried out at the electrode surface, and the ferrocenium methanol acted as the cosubstrate to GOx to catalyze the oxidation of glucose to gluconolactone. In the presence of glucose, the incident collision of a GOx-covered virus onto the UME while ferrocene methanol was being oxidized produced stepwise increases in current as observed by amperometry. These current increases were observed due to the feedback loop of ferrocene methanol to the surface of the electrode after GOx reduces ferrocenium methanol back to ferrocene. Negative controls (i) without glucose, (ii) with an irrelevant virus (murine gammaherpesvirus 68), and (iii) without either virus do not display these current increases. Stepwise current decreases were observed for the prior two negative controls and no discrete events were observed for the latter. We further apply this method to the detection of MCMV in urine of infected mice. The method provides for a selective, rapid, and sensitive detection technique based on electrochemical collisions.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Urina / Compostos Ferrosos / Citomegalovirus / Técnicas Eletroquímicas / Glucose / Glucose Oxidase Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: Proc Natl Acad Sci U S A Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Urina / Compostos Ferrosos / Citomegalovirus / Técnicas Eletroquímicas / Glucose / Glucose Oxidase Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: Proc Natl Acad Sci U S A Ano de publicação: 2016 Tipo de documento: Article