Your browser doesn't support javascript.
loading
Estimating the Internal Dose for 131I Production Workers From Air Sampling Method.
Hoi, Tran Xuan; Phuong, Huynh Truc; Van Hung, Nguyen.
Afiliação
  • Hoi TX; Faculty of Natural Science, Phu Yen University, 18 Tran Phu Street, Tuy Hoa, Vietnam.
  • Phuong HT; Faculty of Physics and Engineering Physics, VNUHCM-University of Science, 227 Nguyen Van Cu, Ho Chi Minh City, Vietnam.
  • Van Hung N; Faculty of Physics and Engineering Physics, VNUHCM-University of Science, 227 Nguyen Van Cu, Ho Chi Minh City, Vietnam.
Radiat Prot Dosimetry ; 175(1): 58-64, 2017 Jun 01.
Article em En | MEDLINE | ID: mdl-27655803
Besides the most common methods of internal dose assessment from inhaled 131I, that are thyroid monitoring and urine analysis, air sampling is a possible way but rarely used for dose estimate. This study aimed to focus on the utilisation of portable air sampler to estimate the internal dose for workers working at 131I production facility. In addition, internal dose estimated from urine analysis at the same time was carried out for comparison. Based on this research, it was found that air monitoring can be done efficiently as urine monitoring if the following conditions are met: (1) the indoor areas are not large, (2) sampling sites need to be placed as near breathing zone as possible and (3) the time-micro-environment patterns of monitored workers are collected carefully.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Monitoramento Ambiental / Exposição Ocupacional / Radioisótopos do Iodo Limite: Humans Idioma: En Revista: Radiat Prot Dosimetry Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Vietnã