Cadmium(II)-based metal-organic nanotubes as solid-phase microextraction coating for ultratrace-level analysis of polychlorinated biphenyls in seawater samples.
Sheng, Wan-Ru; Chen, Yue; Wang, Shan-Shan; Wang, Xiao-Li; Wang, Ming-Lin; Zhao, Ru-Song.
Afiliação
  • Sheng WR; Key Laboratory for Applied Technology of Sophisticated Analytical Instruments of Shandong Province, Analysis and Test Centre, Shandong Academy of Sciences, Jinan, 250014, China.
  • Chen Y; College of Food Science and Engineering, Shandong Agricultural University, Taian, 271018, China.
  • Wang SS; Key Laboratory for Applied Technology of Sophisticated Analytical Instruments of Shandong Province, Analysis and Test Centre, Shandong Academy of Sciences, Jinan, 250014, China.
  • Wang XL; Key Laboratory for Applied Technology of Sophisticated Analytical Instruments of Shandong Province, Analysis and Test Centre, Shandong Academy of Sciences, Jinan, 250014, China.
  • Wang ML; Key Laboratory for Applied Technology of Sophisticated Analytical Instruments of Shandong Province, Analysis and Test Centre, Shandong Academy of Sciences, Jinan, 250014, China.
  • Zhao RS; College of Food Science and Engineering, Shandong Agricultural University, Taian, 271018, China. mlwang@sdau.edu.cn.
Anal Bioanal Chem ; 408(29): 8289-8297, 2016 Nov.
Article em En | MEDLINE | ID: mdl-27704175
ABSTRACT
In this study, stable cadmium(II)-based metal-organic nanotubes (Cd-MONTs) were prepared and used as a coating material for solid-phase microextraction (SPME) of polychlorinated biphenyls (PCBs) from environmental water samples. The as-prepared Cd-MONT SPME coating material was characterized by thermal gravimetric analysis, scanning electron microscopy, and X-ray diffraction. The synthesized Cd-MONTs exhibited high thermal stability (385 °C) and excellent extraction performance toward PCBs. The important conditions were optimized systematically by the response surface method. Under the optimal conditions, the new fiber achieved high enrichment factors (938-3417), low limits of detection (1.80-8.73 pg L-1), and wide linearity (10-5000 pg L-1). The method developed was used in ultratrace-level analysis of PCBs in seawater samples, with satisfactory results for each sample.