Studying the effect of microwave heating on the digestion process and identification of proteins.
Devi, Shobha; Wu, Bo-Hung; Chu, Pei-Yu; Liu, Yue-Pei; Wu, Hsin-Lin; Ho, Yen-Peng.
Afiliação
  • Devi S; Department of Chemistry, National Dong Hwa University, Hualien, Taiwan.
  • Wu BH; Department of Chemistry, National Dong Hwa University, Hualien, Taiwan.
  • Chu PY; Department of Chemistry, National Dong Hwa University, Hualien, Taiwan.
  • Liu YP; Department of Chemistry, National Dong Hwa University, Hualien, Taiwan.
  • Wu HL; Department of Chemistry, National Dong Hwa University, Hualien, Taiwan.
  • Ho YP; Department of Chemistry, National Dong Hwa University, Hualien, Taiwan.
Electrophoresis ; 38(3-4): 429-440, 2017 02.
Article em En | MEDLINE | ID: mdl-27770443
ABSTRACT
The impact of microwave irradiation on the in-solution digestion processes and the detection limit of proteins are systematically studied. Kinetic processes of many peptides produced through the trypsin digestion of various proteins under microwave heating at 50°C were investigated with MALDI-MS. This study also examines the detection limits and digestion completeness of individual proteins under microwave heating at 50°C and at different time intervals (1, 5 and 30 min) using LC-MS. We conclude that if the peptides without missed cleavage dictate the detection limit, conventional digestion will lead to a better detection limit. The detection limit may not differ between the microwave and conventional heating if the peptides with missed cleavage sites and strong intensity are formed at the very early stage (i.e., less than 1 min) and are not further digested throughout the entire digestion process. The digestion of Escherichia coli lysate was compared under conventional and short time (microwave) conditions. The number of proteins identified under conventional heating exceeded that obtained from microwave heating over heating periods less than 5 min. The overall results show that the microwave-assisted digestion is not complete. Although the sequence coverage might be better, the detection limit might be worse than that under conventional heating.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fragmentos de Peptídeos / Proteínas / Micro-Ondas Tipo de estudo: Diagnostic_studies Limite: Animals / Humans Idioma: En Revista: Electrophoresis Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Taiwan

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fragmentos de Peptídeos / Proteínas / Micro-Ondas Tipo de estudo: Diagnostic_studies Limite: Animals / Humans Idioma: En Revista: Electrophoresis Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Taiwan