Dynamic X-ray diffraction sampling for protein crystal positioning.
Scarborough, Nicole M; Godaliyadda, G M Dilshan P; Ye, Dong Hye; Kissick, David J; Zhang, Shijie; Newman, Justin A; Sheedlo, Michael J; Chowdhury, Azhad U; Fischetti, Robert F; Das, Chittaranjan; Buzzard, Gregery T; Bouman, Charles A; Simpson, Garth J.
Afiliação
  • Scarborough NM; Department of Chemistry, Purdue University, West Lafayette, IN 47907, USA.
  • Godaliyadda GM; Department of Electrical and Computer Engineering, Purdue University, West Lafayette, IN 47907, USA.
  • Ye DH; Department of Electrical and Computer Engineering, Purdue University, West Lafayette, IN 47907, USA.
  • Kissick DJ; GM/CA@APS, X-ray Science Division, Argonne National Laboratory, Lemont, IL 60439, USA.
  • Zhang S; Department of Chemistry, Purdue University, West Lafayette, IN 47907, USA.
  • Newman JA; Department of Chemistry, Purdue University, West Lafayette, IN 47907, USA.
  • Sheedlo MJ; Department of Chemistry, Purdue University, West Lafayette, IN 47907, USA.
  • Chowdhury AU; Department of Chemistry, Purdue University, West Lafayette, IN 47907, USA.
  • Fischetti RF; GM/CA@APS, X-ray Science Division, Argonne National Laboratory, Lemont, IL 60439, USA.
  • Das C; Department of Chemistry, Purdue University, West Lafayette, IN 47907, USA.
  • Buzzard GT; Department of Mathematics, Purdue University, West Lafayette, IN 47907, USA.
  • Bouman CA; Department of Electrical and Computer Engineering, Purdue University, West Lafayette, IN 47907, USA.
  • Simpson GJ; Department of Chemistry, Purdue University, West Lafayette, IN 47907, USA.
J Synchrotron Radiat ; 24(Pt 1): 188-195, 2017 01 01.
Article em En | MEDLINE | ID: mdl-28009558
ABSTRACT
A sparse supervised learning approach for dynamic sampling (SLADS) is described for dose reduction in diffraction-based protein crystal positioning. Crystal centering is typically a prerequisite for macromolecular diffraction at synchrotron facilities, with X-ray diffraction mapping growing in popularity as a mechanism for localization. In X-ray raster scanning, diffraction is used to identify the crystal positions based on the detection of Bragg-like peaks in the scattering patterns; however, this additional X-ray exposure may result in detectable damage to the crystal prior to data collection. Dynamic sampling, in which preceding measurements inform the next most information-rich location to probe for image reconstruction, significantly reduced the X-ray dose experienced by protein crystals during positioning by diffraction raster scanning. The SLADS algorithm implemented herein is designed for single-pixel measurements and can select a new location to measure. In each step of SLADS, the algorithm selects the pixel, which, when measured, maximizes the expected reduction in distortion given previous measurements. Ground-truth diffraction data were obtained for a 5 µm-diameter beam and SLADS reconstructed the image sampling 31% of the total volume and only 9% of the interior of the crystal greatly reducing the X-ray dosage on the crystal. Using in situ two-photon-excited fluorescence microscopy measurements as a surrogate for diffraction imaging with a 1 µm-diameter beam, the SLADS algorithm enabled image reconstruction from a 7% sampling of the total volume and 12% sampling of the interior of the crystal. When implemented into the beamline at Argonne National Laboratory, without ground-truth images, an acceptable reconstruction was obtained with 3% of the image sampled and approximately 5% of the crystal. The incorporation of SLADS into X-ray diffraction acquisitions has the potential to significantly minimize the impact of X-ray exposure on the crystal by limiting the dose and area exposed for image reconstruction and crystal positioning using data collection hardware present in most macromolecular crystallography end-stations.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Difração de Raios X / Proteínas / Cristalografia por Raios X Idioma: En Revista: J Synchrotron Radiat Assunto da revista: RADIOLOGIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Difração de Raios X / Proteínas / Cristalografia por Raios X Idioma: En Revista: J Synchrotron Radiat Assunto da revista: RADIOLOGIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Estados Unidos