Midterm results of the fenestrated Anaconda endograft for short-neck infrarenal and juxtarenal abdominal aortic aneurysm repair.
Blankensteijn, Louise L; Dijkstra, Martijn L; Tielliu, Ignace F J; Reijnen, Michel M P J; Zeebregts, Clark J.
Afiliação
  • Blankensteijn LL; Division of Vascular Surgery, Department of Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.
  • Dijkstra ML; Division of Vascular Surgery, Department of Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.
  • Tielliu IF; Division of Vascular Surgery, Department of Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.
  • Reijnen MM; Department of Surgery, Rijnstate Hospital, Arnhem, The Netherlands.
  • Zeebregts CJ; Division of Vascular Surgery, Department of Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands. Electronic address: czeebregts@hotmail.com.
J Vasc Surg ; 65(2): 303-310, 2017 Feb.
Article em En | MEDLINE | ID: mdl-28029566
OBJECTIVE: The fenestrated Anaconda endograft (Vascutek, Renfrewshire, Scotland) was introduced in 2010 and showed promising short-term results with high technical success and low morbidity rates. The aim of this study was to present the midterm results, with a minimum of 12 months follow-up, for all patients treated with the fenestrated Anaconda endograft in The Netherlands. METHODS: Patients treated with the fenestrated Anaconda endograft between May 2011 and February 2015 were included. Follow-up consisted of computed tomography angiography at 1 month and 1 year, and duplex ultrasound yearly thereafter with additional computed tomography angiography if indicated using a standard protocol. RESULTS: A total of 60 patients were included; 48 patients (80.0%) were treated for juxtarenal aneurysms, and 12 (20.0%) were short-neck infrarenal aneurysms. Mean aneurysm size was 64 ± 9 mm. A total of 140 fenestrations were incorporated. Median follow-up was 16.4 months (interquartile range, 11.9-27.4). The 30-day mortality was 3.4% (n = 2). Kaplan-Meier estimates for 1-year, 2-year, and 3-year survival were 91.4%, 89.5%, and 86.3%, respectively, without aneurysm-related mortality during follow-up. Main body primary and secondary endograft patencies were 98.3% and 100%, respectively. Target vessel primary and secondary patencies were 95.0% and 98.6%, respectively. Early type IA endoleaks occurred in seven patients (11.7%) and spontaneously resolved in all patients. At 1-year follow-up 4 (6.7%) type II endoleaks persisted. One patient experienced aneurysm rupture because of a late type III endoleak attributable to a dislodged renal stent and subsequently underwent successful conversion to open surgery. CONCLUSIONS: The fenestrated Anaconda is a viable treatment option for complex abdominal aortic aneurysms. Acceptable mortality and morbidity and low reintervention rates contribute to good midterm results. Occurrence of early type I endoleak was relatively common, but these resolved spontaneously in all patients.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Prótese Vascular / Stents / Aneurisma da Aorta Abdominal / Implante de Prótese Vascular / Procedimentos Endovasculares Tipo de estudo: Etiology_studies / Guideline / Observational_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male País/Região como assunto: Europa Idioma: En Revista: J Vasc Surg Assunto da revista: ANGIOLOGIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Prótese Vascular / Stents / Aneurisma da Aorta Abdominal / Implante de Prótese Vascular / Procedimentos Endovasculares Tipo de estudo: Etiology_studies / Guideline / Observational_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male País/Região como assunto: Europa Idioma: En Revista: J Vasc Surg Assunto da revista: ANGIOLOGIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Holanda