Cerebral Ventricular Dimensions After Decompressive Craniectomy: A Comparison Between Bedside Sonographic Duplex Technique and Cranial Computed Tomography.
Bendella, Habib; Maegele, Marc; Hartmann, Alexander; Spreer, Joachim; Rommel, Nadine; Lefering, Rolf; Nakamura, Makoto; Igressa, Alhadi.
Afiliação
  • Bendella H; Department of Neurosurgery, Cologne Merheim Medical Center (CMMC), University of Witten/Herdecke, Ostmerheimerstr. 200, 51109, Cologne, Germany. Habib@Bendella.de.
  • Maegele M; Department of Traumatology, Orthopedic Surgery and Sportsmedicine, Cologne-Merheim Medical Center (CMMC), University of Witten/Herdecke, Cologne, Germany.
  • Hartmann A; Institute for Research in Operative Medicine (IFOM), University of Witten/Herdecke, Cologne-Merheim, Cologne, Germany.
  • Spreer J; Department of Neurosurgery, Cologne Merheim Medical Center (CMMC), University of Witten/Herdecke, Ostmerheimerstr. 200, 51109, Cologne, Germany.
  • Rommel N; RehaNova Rehabilitation Hospital, Cologne-Merheim, Cologne, Germany.
  • Lefering R; Division of Neuroradiology, Department of Radiology, Cologne Merheim Medical Center (CMMC), University of Witten/Herdecke, Cologne, Germany.
  • Nakamura M; RehaNova Rehabilitation Hospital, Cologne-Merheim, Cologne, Germany.
  • Igressa A; Institute for Research in Operative Medicine (IFOM), University of Witten/Herdecke, Cologne-Merheim, Cologne, Germany.
Neurocrit Care ; 26(3): 321-329, 2017 Jun.
Article em En | MEDLINE | ID: mdl-28054287
ABSTRACT

BACKGROUND:

The objective of this study was to assess and compare ventricle diameters in patients after decompressive craniectomy by using cranial computed tomography (CCT) versus sonographic duplex technique (SDT).

METHODS:

A total of 102 consecutive patients after decompressive craniectomy following brain infarct, bleeding and trauma were examined by CCT and SDT. SDT was performed within 24 h after repeated postinterventional control CCT and the correlation between both methods was assessed via measurement of dimensions of all four ventricles. In addition, midline shifts and overall cerebral anatomy was evaluated.

RESULTS:

A high correlation was found between CCT and SDT in measuring the diameters of all four ventricles (right lateral r = 0.978, p < 0.001; left lateral r = 0.975, p < 0.001; third r = 0.987, p < 0.001 and fourth ventricle r = 0.954, p < 0.001). Deviations of midline structure was observed in SDT as well as in CCT (r = 0.992, p < 0.001).

CONCLUSION:

SDT in patients after decompressive craniectomy may represent an additional bedside tool to assess the dimensions of the ventricular system, anatomical structures, e.g., subdural hygromas, hematomas, midline shifts, gyri and sulci. The measurement of the dimensions of all four ventricles by using SDT delivers accurate values and may be considered as an alternative to CCT or a trigger for CCT prior to further treatment.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Hemorragia Cerebral / Infarto Cerebral / Ventrículos Cerebrais / Avaliação de Resultados em Cuidados de Saúde / Ultrassonografia Doppler Dupla / Craniectomia Descompressiva / Lesões Encefálicas Traumáticas Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Neurocrit Care Assunto da revista: NEUROLOGIA / TERAPIA INTENSIVA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Hemorragia Cerebral / Infarto Cerebral / Ventrículos Cerebrais / Avaliação de Resultados em Cuidados de Saúde / Ultrassonografia Doppler Dupla / Craniectomia Descompressiva / Lesões Encefálicas Traumáticas Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Neurocrit Care Assunto da revista: NEUROLOGIA / TERAPIA INTENSIVA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Alemanha