Your browser doesn't support javascript.
loading
Bailout polytetrafluoroethylene-covered stent implantation for left main bifurcation perforation using the kissing stent technique.
Moriyama, Noriaki; Tanaka, Yutaka; Saito, Shigeru.
Afiliação
  • Moriyama N; Department of Cardiology and Catheterization Laboratory, Shonan Kamakura General Hospital, Kamakura, Japan.
  • Tanaka Y; Department of Cardiology and Catheterization Laboratory, Shonan Kamakura General Hospital, Kamakura, Japan.
  • Saito S; Department of Cardiology and Catheterization Laboratory, Shonan Kamakura General Hospital, Kamakura, Japan.
Catheter Cardiovasc Interv ; 89(6): 1022-1027, 2017 May.
Article em En | MEDLINE | ID: mdl-28145616
ABSTRACT
Coronary artery perforation during percutaneous coronary intervention is a rare, but potentially lethal complication. Immediate balloon expansion at the perforation site can halt the bleeding. Implantation of a coronary polytetrafluoroethylene (PTFE)-covered stent enables the efficient endovascular repair of a coronary artery perforation. However, if the perforation occurs at a bifurcation, a PTFE-covered stent may jail the side branch. We report a difficult case of blowout coronary perforation (Ellis type III) at a left main coronary artery bifurcation, which was successfully sealed with a PTFE-covered stent without interference with the side branch coronary artery circulation. This new strategy might represent a useful salvage option for some patients with a coronary bifurcation perforation. © 2017 Wiley Periodicals, Inc.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Politetrafluoretileno / Angioplastia Coronária com Balão / Stents / Vasos Coronários / Materiais Revestidos Biocompatíveis / Estenose Coronária / Traumatismos Cardíacos Tipo de estudo: Etiology_studies Limite: Aged / Female / Humans Idioma: En Revista: Catheter Cardiovasc Interv Assunto da revista: CARDIOLOGIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Politetrafluoretileno / Angioplastia Coronária com Balão / Stents / Vasos Coronários / Materiais Revestidos Biocompatíveis / Estenose Coronária / Traumatismos Cardíacos Tipo de estudo: Etiology_studies Limite: Aged / Female / Humans Idioma: En Revista: Catheter Cardiovasc Interv Assunto da revista: CARDIOLOGIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Japão