Your browser doesn't support javascript.
loading
Objective monitoring of Insecticide-treated bednet use to improve malaria prevention: SmartNet development and validation.
Krezanoski, Paul J; Campbell, Jeffrey I; Santorino, Data; Bangsberg, David R.
Afiliação
  • Krezanoski PJ; Department of Medicine, Zuckerberg San Francisco General Hospital, University of California, San Francisco, San Francisco, California, United States of America.
  • Campbell JI; Department of Pediatrics, Zuckerberg San Francisco General Hospital, University of California, San Francisco, San Francisco, California, United States of America.
  • Santorino D; Harvard Medical School, Boston, Massachusetts, United States of America.
  • Bangsberg DR; Mbarara University of Science and Technology, Mbarara, Uganda.
PLoS One ; 12(2): e0168116, 2017.
Article em En | MEDLINE | ID: mdl-28158233
ABSTRACT
Malaria is a serious health concern for three billion people worldwide, killing nearly 600,000 people a year. Insecticide-treated bednets (ITNs) are an effective and valuable tool for preventing malaria and hundreds of millions of ITNs have been distributed throughout sub-Saharan Africa. Nevertheless, our current methods for measuring ITN use are inadequate to inform malaria prevention programs. The most common method, self-reported ITN use, is limited by 1) social desirability, 2) recall and 3) sampling bias. An acceptable objective and longitudinal method of assessing adherence to ITN use would improve our ability to better understand the determinants of ITN use and design more effective malaria prevention interventions. We describe the development and initial proof-of-concept validity testing of an ITN adherence monitoring tool called SmartNet. SmartNet uses conductive thread interwoven into an ITN and a microcontroller to detect the state of the ITN. We tested SmartNet among five volunteers using the device over their beds in Boston, USA for two weeks with the goal of evaluating device reliability, accuracy and acceptability to inform future device improvements. The device recorded data for 63.1% (35172/55711) of installed two-minute time intervals, with 97.3% (19990/20539) of the recording errors relating to battery failures. Overall, the device was 71.7% (25204/35172) accurate in determining the state of the ITN (whether it was folded up or unfurled) and performed significantly better at detecting an unfurled ITN than a folded ITN, 77.3% versus 68.4% (p<0.001). Participants noted no significant acceptability concerns and all participants felt SmartNet was easy or very easy to use. SmartNet is a novel approach to objectively measure ITN adherence over time. Our results suggest a variety of device improvements to both extend reliability and improve performance of SmartNet prior to deployment in a malaria-endemic setting.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Mosquiteiros Tratados com Inseticida / Inseticidas / Malária Tipo de estudo: Prognostic_studies Limite: Adult / Female / Humans / Male Idioma: En Revista: PLoS One Assunto da revista: CIENCIA / MEDICINA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Mosquiteiros Tratados com Inseticida / Inseticidas / Malária Tipo de estudo: Prognostic_studies Limite: Adult / Female / Humans / Male Idioma: En Revista: PLoS One Assunto da revista: CIENCIA / MEDICINA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Estados Unidos