Your browser doesn't support javascript.
loading
Revision Total Hip Arthroplasty for Fractured Ceramic Bearings: A Review of Best Practices for Revision Cases.
Rambani, Rohit; Kepecs, David M; Mäkinen, Tatu J; Safir, Oleg A; Gross, Allan E; Kuzyk, Paul R.
Afiliação
  • Rambani R; Department of Orthopaedics, United Lincolnshire Hospital NHS Trust, Boston, Lincolnshire, UK.
  • Kepecs DM; Division of Orthopaedic Surgery, Department of Surgery, University of Toronto, Mount Sinai Hospital, Toronto, ON, Canada.
  • Mäkinen TJ; Division of Orthopaedic Surgery, Department of Surgery, University of Toronto, Mount Sinai Hospital, Toronto, ON, Canada.
  • Safir OA; Division of Orthopaedic Surgery, Department of Surgery, University of Toronto, Mount Sinai Hospital, Toronto, ON, Canada.
  • Gross AE; Division of Orthopaedic Surgery, Department of Surgery, University of Toronto, Mount Sinai Hospital, Toronto, ON, Canada.
  • Kuzyk PR; Division of Orthopaedic Surgery, Department of Surgery, University of Toronto, Mount Sinai Hospital, Toronto, ON, Canada.
J Arthroplasty ; 32(6): 1959-1964, 2017 06.
Article em En | MEDLINE | ID: mdl-28189439
BACKGROUND: Total hip arthroplasty revision for a fractured ceramic bearing is rare but offers unique challenges. The purpose of this review was to provide a summary of existing literature on fractured ceramic bearings. METHODS: Two authors performed a literature search of the MEDLINE OVID and PubMed databases with the following search terms: ceramic, fracture, total hip arthroplasty, and revision. RESULTS: The search identified 228 articles of which 199 were selected for review. CONCLUSIONS: It is mandatory to perform a complete synovectomy and thorough debridement of the fractured ceramic fragments. A well-fixed acetabular component should be removed if either the locking mechanism is damaged or the component is malpositioned. If the femoral stem taper is damaged, the femoral stem should be removed. However, if minimal damage is present, the femoral stem may be retained and revised using a fourth generation ceramic head with a titanium sleeve. Metal bearings should be avoided and revision with ceramic bearings should be performed whenever possible.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Reoperação / Falha de Prótese / Cerâmica / Artroplastia de Quadril / Prótese de Quadril Tipo de estudo: Etiology_studies / Guideline / Prognostic_studies / Risk_factors_studies / Systematic_reviews Limite: Aged / Humans / Middle aged Idioma: En Revista: J Arthroplasty Assunto da revista: ORTOPEDIA Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Reoperação / Falha de Prótese / Cerâmica / Artroplastia de Quadril / Prótese de Quadril Tipo de estudo: Etiology_studies / Guideline / Prognostic_studies / Risk_factors_studies / Systematic_reviews Limite: Aged / Humans / Middle aged Idioma: En Revista: J Arthroplasty Assunto da revista: ORTOPEDIA Ano de publicação: 2017 Tipo de documento: Article