Your browser doesn't support javascript.
loading
Is C1 lateral mass screw placement safe for the Chinese, Indians, and Malays? An analysis of 180 computed tomography scans.
Lee, C K; Tan, T S; Chan, Cyw; Kwan, M K.
Afiliação
  • Lee CK; 1 NOCERAL, Department of Orthopedic Surgery, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia.
  • Tan TS; 1 NOCERAL, Department of Orthopedic Surgery, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia.
  • Chan C; 1 NOCERAL, Department of Orthopedic Surgery, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia.
  • Kwan MK; 1 NOCERAL, Department of Orthopedic Surgery, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia.
J Orthop Surg (Hong Kong) ; 25(1): 2309499017692683, 2017 01.
Article em En | MEDLINE | ID: mdl-28211302
INTRODUCTION: C1 lateral mass (C1LM) screw is a common procedure in spine surgery. However, related studies are lacking in Asia. We aim to determine the safety of C1LM screw for the Chinese, Indians, and Malays. METHODS: Three-dimensional computed tomographies of 180 subjects (60 from each ethnic) were analyzed. The length and angulations of C1LM screw and the location of internal carotid artery (ICA) in relation to C1LM were assessed and classified according to the classification by Murakami et al. The incidence of ponticulus posticus (PP) was determined and the differences among the population of these three ethnics were recorded. RESULTS: The average base length was 8.5 ± 1.4 mm. The lengths within the lateral mass were between 14.7 ± 1.6 mm and 21.7 ± 2.3 mm. The prevalence of PP was 8.3%. 55.3% (199) of ICA were located in zone 0, 38.3% (138) in zone 1-1, 6.4% (23) in zone 1-2, and none in zone 1-3 and zone 2. The average angulation from the entry point to the ICA was 8.5° ± 6.4° laterally. The mean distance of ICA from C1 anterior cortex was 3.7 ± 1.7 mm (range: 0.6∼11.3). There was no difference in distribution of ICA in zone 1 among the three population (Chinese-47%, Indians-61%, and Malays-53%; p > 0.05). CONCLUSIONS: No ICA is located medial to the entry point of C1LM screw. If bicortical purchase of C1LM screw is needed, screw protrusion of less than 3 mm or medially angulated is safe for ICA. The incidence of PP is 8.3% with higher prevalence among the Indian population.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Atlas Cervical / Doenças da Coluna Vertebral / Fusão Vertebral / Parafusos Ósseos / Tomografia Computadorizada por Raios X / Imageamento Tridimensional Tipo de estudo: Diagnostic_studies / Observational_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged País/Região como assunto: Asia Idioma: En Revista: J Orthop Surg (Hong Kong) Assunto da revista: ORTOPEDIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Malásia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Atlas Cervical / Doenças da Coluna Vertebral / Fusão Vertebral / Parafusos Ósseos / Tomografia Computadorizada por Raios X / Imageamento Tridimensional Tipo de estudo: Diagnostic_studies / Observational_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged País/Região como assunto: Asia Idioma: En Revista: J Orthop Surg (Hong Kong) Assunto da revista: ORTOPEDIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Malásia