Your browser doesn't support javascript.
loading
Effectiveness of feedback with a smartwatch for high-quality chest compressions during adult cardiac arrest: A randomized controlled simulation study.
Ahn, Chiwon; Lee, Juncheol; Oh, Jaehoon; Song, Yeongtak; Chee, Youngjoon; Lim, Tae Ho; Kang, Hyunggoo; Shin, Hyungoo.
Afiliação
  • Ahn C; Department of Emergency Medicine, College of Medicine, Hanyang University, Seoul, Korea.
  • Lee J; Department of Biomedical Engineering, Graduate School of Medicine, Hanyang University, Seoul, Korea.
  • Oh J; Department of Emergency Medicine, College of Medicine, Hanyang University, Seoul, Korea.
  • Song Y; Department of Emergency Medicine, College of Medicine, Hanyang University, Seoul, Korea.
  • Chee Y; Convergence Technology Center for Disaster Preparedness, Hanyang University, Seoul, Korea.
  • Lim TH; Convergence Technology Center for Disaster Preparedness, Hanyang University, Seoul, Korea.
  • Kang H; School of Electrical Engineering, University of Ulsan, Ulsan, Korea.
  • Shin H; Department of Emergency Medicine, College of Medicine, Hanyang University, Seoul, Korea.
PLoS One ; 12(4): e0169046, 2017.
Article em En | MEDLINE | ID: mdl-28369055
Previous studies have demonstrated the potential for using smartwatches with a built-in accelerometer as feedback devices for high-quality chest compression during cardiopulmonary resuscitation. However, to the best of our knowledge, no previous study has reported the effects of this feedback on chest compressions in action. A randomized, parallel controlled study of 40 senior medical students was conducted to examine the effect of chest compression feedback via a smartwatch during cardiopulmonary resuscitation of manikins. A feedback application was developed for the smartwatch, in which visual feedback was provided for chest compression depth and rate. Vibrations from smartwatch were used to indicate the chest compression rate. The participants were randomly allocated to the intervention and control groups, and they performed chest compressions on manikins for 2 min continuously with or without feedback, respectively. The proportion of accurate chest compression depth (≥5 cm and ≤6 cm) was assessed as the primary outcome, and the chest compression depth, chest compression rate, and the proportion of complete chest decompression (≤1 cm of residual leaning) were recorded as secondary outcomes. The proportion of accurate chest compression depth in the intervention group was significantly higher than that in the control group (64.6±7.8% versus 43.1±28.3%; p = 0.02). The mean compression depth and rate and the proportion of complete chest decompressions did not differ significantly between the two groups (all p>0.05). Cardiopulmonary resuscitation-related feedback via a smartwatch could provide assistance with respect to the ideal range of chest compression depth, and this can easily be applied to patients with out-of-hospital arrest by rescuers who wear smartwatches.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Microcomputadores / Reanimação Cardiopulmonar / Parada Cardíaca / Manequins Tipo de estudo: Clinical_trials Limite: Adolescent / Adult / Female / Humans / Male País/Região como assunto: Asia Idioma: En Revista: PLoS One Assunto da revista: CIENCIA / MEDICINA Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Microcomputadores / Reanimação Cardiopulmonar / Parada Cardíaca / Manequins Tipo de estudo: Clinical_trials Limite: Adolescent / Adult / Female / Humans / Male País/Região como assunto: Asia Idioma: En Revista: PLoS One Assunto da revista: CIENCIA / MEDICINA Ano de publicação: 2017 Tipo de documento: Article