Your browser doesn't support javascript.
loading
Multi-point measurement using two-channel reflectometer with antenna switching for study of high-frequency fluctuations in GAMMA 10.
Ikezoe, R; Ichimura, M; Okada, T; Itagaki, J; Hirata, M; Sumida, S; Jang, S; Izumi, K; Tanaka, A; Yoshikawa, M; Kohagura, J; Sakamoto, M; Nakashima, Y.
Afiliação
  • Ikezoe R; Plasma Research Center, University of Tsukuba, Tsukuba 305-8577, Japan.
  • Ichimura M; Plasma Research Center, University of Tsukuba, Tsukuba 305-8577, Japan.
  • Okada T; Plasma Research Center, University of Tsukuba, Tsukuba 305-8577, Japan.
  • Itagaki J; Plasma Research Center, University of Tsukuba, Tsukuba 305-8577, Japan.
  • Hirata M; Plasma Research Center, University of Tsukuba, Tsukuba 305-8577, Japan.
  • Sumida S; Plasma Research Center, University of Tsukuba, Tsukuba 305-8577, Japan.
  • Jang S; Plasma Research Center, University of Tsukuba, Tsukuba 305-8577, Japan.
  • Izumi K; Plasma Research Center, University of Tsukuba, Tsukuba 305-8577, Japan.
  • Tanaka A; Plasma Research Center, University of Tsukuba, Tsukuba 305-8577, Japan.
  • Yoshikawa M; Plasma Research Center, University of Tsukuba, Tsukuba 305-8577, Japan.
  • Kohagura J; Plasma Research Center, University of Tsukuba, Tsukuba 305-8577, Japan.
  • Sakamoto M; Plasma Research Center, University of Tsukuba, Tsukuba 305-8577, Japan.
  • Nakashima Y; Plasma Research Center, University of Tsukuba, Tsukuba 305-8577, Japan.
Rev Sci Instrum ; 88(3): 033504, 2017 Mar.
Article em En | MEDLINE | ID: mdl-28372363
ABSTRACT
A two-channel microwave reflectometer system with fast microwave antenna switching capability was developed and applied to the GAMMA 10 tandem mirror device to study high-frequency small-amplitude fluctuations in a hot mirror plasma. The fast switching of the antennas is controlled using PIN diode switches, which offers the significant advantage of reducing the number of high-cost microwave components and digitizers with high bandwidths and large memory that are required to measure the spatiotemporal behavior of the high-frequency fluctuations. The use of two channels rather than one adds the important function of a simultaneous two-point measurement in either the radial direction or the direction of the antenna array to measure the phase profile of the fluctuations along with the normal amplitude profile. The density fluctuations measured using this system clearly showed the high-frequency coherent fluctuations that are associated with Alfvén-ion-cyclotron (AIC) waves in GAMMA 10. A correlation analysis applied to simultaneously measured density fluctuations showed that the phase component that was included in a reflected microwave provided both high coherence and a clear phase difference for the AIC waves, while the amplitude component showed neither significant coherence nor clear phase difference. The axial phase differences of the AIC waves measured inside the hot plasma confirmed the formation of a standing wave structure. The axial variation of the radial profiles was evaluated and a clear difference was found among the AIC waves for the first time, which would be a key to clarify the unknown boundary conditions of the AIC waves.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Japão