Your browser doesn't support javascript.
loading
A computational study of invariant I5 in a nearly incompressible transversely isotropic model for white matter.
Feng, Yuan; Qiu, Suhao; Xia, Xiaolong; Ji, Songbai; Lee, Chung-Hao.
Afiliação
  • Feng Y; Center for Molecular Imaging and Nuclear Medicine, School of Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Suzhou, Jiangsu 215123, China; School of Mechanical and Electronic Eng
  • Qiu S; Center for Molecular Imaging and Nuclear Medicine, School of Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Suzhou, Jiangsu 215123, China; School of Electronic and Information En
  • Xia X; Center for Molecular Imaging and Nuclear Medicine, School of Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Suzhou, Jiangsu 215123, China; School of Electronic and Information En
  • Ji S; Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, USA.
  • Lee CH; School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA; Institute for Computational Engineering and Sciences, The University of Texas at Austin, Austin, TX 78712, USA.
J Biomech ; 57: 146-151, 2017 05 24.
Article em En | MEDLINE | ID: mdl-28433390
The aligned axonal fiber bundles in white matter make it suitable to be modeled as a transversely isotropic material. Recent experimental studies have shown that a minimal form, nearly incompressible transversely isotropic (MITI) material model, is capable of describing mechanical anisotropy of white matter. Here, we used a finite element (FE) computational approach to demonstrate the significance of the fifth invariant (I5) when modeling the anisotropic behavior of white matter in the large-strain regime. We first implemented and validated the MITI model in an FE simulation framework for large deformations. Next, we applied the model to a plate-hole structural problem to highlight the significance of the invariant I5 by comparing with the standard fiber reinforcement (SFR) model. We also compared the two models by fitting the experiment data of asymmetric indentation, shear test, and uniaxial stretch of white matter. Our results demonstrated the significance of I5 in describing shear deformation/anisotropy, and illustrated the potential of the MITI model to characterize transversely isotropic white matter tissues in the large-strain regime.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Substância Branca / Modelos Biológicos Limite: Humans Idioma: En Revista: J Biomech Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Substância Branca / Modelos Biológicos Limite: Humans Idioma: En Revista: J Biomech Ano de publicação: 2017 Tipo de documento: Article