Your browser doesn't support javascript.
loading
Technical Performance and Clinical Effectiveness of Drop Type With Adjustable Concentrator-Cell Free and Concentrated Ascites Reinfusion Therapy.
Yamada, Yosuke; Harada, Makoto; Yamaguchi, Akinori; Kobayashi, Yasuko; Chino, Takashi; Minowa, Takashi; Kosuge, Takashi; Tsukada, Wataru; Hashimoto, Koji; Kamijo, Yuji.
Afiliação
  • Yamada Y; Department of Nephrology, Shinshu University School of Medicine, Matsumoto, Nagano, Japan.
  • Harada M; Department of Nephrology, Shinshu University School of Medicine, Matsumoto, Nagano, Japan.
  • Yamaguchi A; Department of Nephrology, Shinshu University School of Medicine, Matsumoto, Nagano, Japan.
  • Kobayashi Y; Medical Instrumental Management Center, Shinshu University Hospital, Matsumoto, Nagano, Japan.
  • Chino T; Medical Instrumental Management Center, Shinshu University Hospital, Matsumoto, Nagano, Japan.
  • Minowa T; Medical Instrumental Management Center, Shinshu University Hospital, Matsumoto, Nagano, Japan.
  • Kosuge T; Department of Nephrology and Urology, Jishyukai Ueda Kidney Clinic, Ueda, Nagano, Japan.
  • Tsukada W; Department of Nephrology and Urology, Jishyukai Ueda Kidney Clinic, Ueda, Nagano, Japan.
  • Hashimoto K; Department of Nephrology, Shinshu University School of Medicine, Matsumoto, Nagano, Japan.
  • Kamijo Y; Department of Nephrology, Shinshu University School of Medicine, Matsumoto, Nagano, Japan.
Artif Organs ; 41(12): 1135-1144, 2017 Dec.
Article em En | MEDLINE | ID: mdl-28589706
ABSTRACT
Cell-free and concentrated ascites reinfusion therapy (CART) is a very useful treatment method for refractory ascites but is difficult for many hospitals to employ due to its need for specialized equipment. We have therefore developed drop-type with adjustable concentrator CART (DC-CART) that uses a drop-type filtration mechanism and requires only a simple pump and pressure monitor for its concentration process. Easy adjustment of ascites concentration is possible through a recirculation loop, and filter membrane washing is aided by DC-CART's external pressure-type filtration to enable the processing of any quality or quantity of ascites. Moreover, the absence of a roller pump before filtration avoids inflammatory substance release from compressed cells. A total of 268 sessions of DC-CART using ascites from 98 patients were performed with good clinical results at our hospitals between January 2012 and June 2016. This report presents the detailed methods of DC-CART and summarizes its clinical effectiveness using patient ascites and blood data obtained from 59 sessions between March 2015 and February 2016. This novel technique successfully processed refractory ascites in numerous diseases with no serious adverse events. DC-CART could concentrate large amounts of ascites (from median weight 4900 g [max 20 200 g] to median weight 695 g; median concentration ratio 7.4), and a high amount of protein (median weight 73 g [max 294 g]) could be reinfused. Serum albumin levels were significantly increased (P = 0.010) and kidney function and systemic hemodynamics were well maintained in treated subjects. Additional concentration of ascites and adjustment of ascites volume were easily performed by recirculation (from median weight 615 g to median weight 360 g; median concentration ratio 1.5). Time was needed during DC-CART for filter membrane cleaning, especially for viscous ascites. Overall, DC-CART represents a safe and useful treatment method for various forms of refractory ascites that can be performed at a wide range of health care institutions.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ascite / Filtração Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Artif Organs Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ascite / Filtração Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Artif Organs Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Japão