Your browser doesn't support javascript.
loading
Development of the breast immobilization system in prone setup: The effect of bra in prone position to improve the breast setup error.
Kawamura, Mariko; Maeda, Yoshikazu; Yamamoto, Kazutaka; Takamatsu, Shigeyuki; Sato, Yoshitaka; Minami, Hiroki; Saga, Yusuke; Kume, Kyo; Tameshige, Yuji; Sasaki, Makoto; Tamamura, Hiroyasu; Ohta, Kouji; Itoh, Yoshiyuki; Naganawa, Shinji.
Afiliação
  • Kawamura M; Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan.
  • Maeda Y; Proton Therapy Center, Fukui Prefectural Hospital, Fukui, Japan.
  • Yamamoto K; Proton Therapy Center, Fukui Prefectural Hospital, Fukui, Japan.
  • Takamatsu S; Department of Radiotherapy, Graduate School of Medical Science, Kanazawa University, Ishikawa, Japan.
  • Sato Y; Proton Therapy Center, Fukui Prefectural Hospital, Fukui, Japan.
  • Minami H; Proton Therapy Center, Fukui Prefectural Hospital, Fukui, Japan.
  • Saga Y; Proton Therapy Center, Fukui Prefectural Hospital, Fukui, Japan.
  • Kume K; Research and Development Division, The Wakasa Wan Energy Research Center, Fukui, Japan.
  • Tameshige Y; Proton Therapy Center, Fukui Prefectural Hospital, Fukui, Japan.
  • Sasaki M; Proton Therapy Center, Fukui Prefectural Hospital, Fukui, Japan.
  • Tamamura H; Proton Therapy Center, Fukui Prefectural Hospital, Fukui, Japan.
  • Ohta K; Department of Surgery, Fukui Prefectural Hospital, Fukui, Japan.
  • Itoh Y; Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan.
  • Naganawa S; Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan.
J Appl Clin Med Phys ; 18(4): 155-160, 2017 Jul.
Article em En | MEDLINE | ID: mdl-28594079
ABSTRACT
PURPOSE/OBJECTIVE(S) Accurate and reproducible positioning of the breast is difficult due to its deformability and softness; thus, targeting a breast tumor or tumor bed with fractionated radiotherapy using external beam radiation is difficult. The aim of this study was to develop a novel bra to aid in breast immobilization in the prone position. MATERIALS &

METHODS:

To assess the accuracy of prone position fixation of breast tumors, 33 breast cancer patients with 34 lesions were recruited. The bra used in this verification was customized from a commercially available bra. Duplicate MRI were acquired in the prone position, alternating with and without the bra, and for each series, patients were asked to step off the MRI table and re-set up in the prone position. Patients were also asked to remove and re-fit the bra for the second MRI. Each pair of images were superimposed to match the shape of the skin surface, and the maximum difference in tumor geometric center in three axes was measured. The required set up margin was calculated as required margin = mean difference in geometric center + 2.5 standard deviation. The volumetric overlap of the tumor, as well as contouring uncertainties, was evaluated using contour analysis software.

RESULTS:

The median breast size was 498 cc. The required margins for the lateral, vertical, and longitudinal directions were estimated to be 4.1, 4.1, and 5.0 mm, respectively, with the bra, and 5.1, 6.9, and 6.7 mm, respectively, without the bra. These margins covered the dislocation of more than 33 lesions in total. With the bra, 33 lesions had achieved an objective overlap of 95% and 99% with 2 and 4 mm margins, respectively, whereas 4 and 8 mm, respectively, were needed without the bra.

CONCLUSION:

The use of an immobilizing bra reduced the setup margin for prone position fixation of breast tumors.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Mama / Neoplasias da Mama / Decúbito Ventral / Vestuário / Posicionamento do Paciente / Erros de Configuração em Radioterapia / Imobilização Limite: Female / Humans Idioma: En Revista: J Appl Clin Med Phys Assunto da revista: BIOFISICA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Mama / Neoplasias da Mama / Decúbito Ventral / Vestuário / Posicionamento do Paciente / Erros de Configuração em Radioterapia / Imobilização Limite: Female / Humans Idioma: En Revista: J Appl Clin Med Phys Assunto da revista: BIOFISICA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Japão