Chip-on-the-tip compact flexible endoscopic epifluorescence video-microscope for in-vivo imaging in medicine and biomedical research.
Matz, Gregor; Messerschmidt, Bernhard; Göbel, Werner; Filser, Severin; Betz, Christian S; Kirsch, Matthias; Uckermann, Ortrud; Kunze, Marcel; Flämig, Sven; Ehrhardt, André; Irion, Klaus-Martin; Haack, Mareike; Dorostkar, Mario M; Herms, Jochen; Gross, Herbert.
Afiliação
  • Matz G; GRINTECH GmbH, Schillerstrasse 1, 07743 Jena, Germany.
  • Messerschmidt B; Institute of Applied Physics, FSU Jena, Fürstengraben 1, 07737 Jena, Germany.
  • Göbel W; GRINTECH GmbH, Schillerstrasse 1, 07743 Jena, Germany.
  • Filser S; KARL STORZ GmbH & Co. KG, Mittelstrasse 8, 78532 Tuttlingen, Germany.
  • Betz CS; LMU Munich, Geschwister-Scholl-Platz 1, 80539 Munich, Germany.
  • Kirsch M; Klinikum Großhadern, Marchioninistr. 13, 81377 Munich, Germany.
  • Uckermann O; Neurosurgery, University Hospital Carl Gustav Carus, TU Dresden, Fetscherstrasse 74, 01307 Dresden, Germany.
  • Kunze M; Neurosurgery, University Hospital Carl Gustav Carus, TU Dresden, Fetscherstrasse 74, 01307 Dresden, Germany.
  • Flämig S; GRINTECH GmbH, Schillerstrasse 1, 07743 Jena, Germany.
  • Ehrhardt A; GRINTECH GmbH, Schillerstrasse 1, 07743 Jena, Germany.
  • Irion KM; KARL STORZ GmbH & Co. KG, Mittelstrasse 8, 78532 Tuttlingen, Germany.
  • Haack M; KARL STORZ GmbH & Co. KG, Mittelstrasse 8, 78532 Tuttlingen, Germany.
  • Dorostkar MM; Klinikum Großhadern, Marchioninistr. 13, 81377 Munich, Germany.
  • Herms J; LMU Munich, Geschwister-Scholl-Platz 1, 80539 Munich, Germany.
  • Gross H; LMU Munich, Geschwister-Scholl-Platz 1, 80539 Munich, Germany.
Biomed Opt Express ; 8(7): 3329-3342, 2017 Jul 01.
Article em En | MEDLINE | ID: mdl-28717570
ABSTRACT
We demonstrate a 60 mg light video-endomicroscope with a cylindrical shape of the rigid tip of only 1.6 mm diameter and 6.7 mm length. A novel implementation method of the illumination unit in the endomicroscope is presented. It allows for the illumination of the biological sample with fiber-coupled LED light at 455 nm and the imaging of the red-shifted fluorescence light above 500 nm in epi-direction. A large numerical aperture of 0.7 leads to a sub-cellular resolution and yields to high-contrast images within a field of view of 160 µm. A miniaturized chip-on-the-tip CMOS image sensor with more than 150,000 pixels captures the multicolor images at 30 fps. Considering size, plug-and-play capability, optical performance, flexibility and weight, we hence present a probe which sets a new benchmark in the field of epifluorescence endomicroscopes. Several ex-vivo and in-vivo experiments in rodents and humans suggest future application in biomedical fields, especially in the neuroscience community, as well as in medical applications targeting optical biopsies or the detection of cellular anomalies.