Your browser doesn't support javascript.
loading
Comparison of intravoxel incoherent motion diffusion-weighted imaging between turbo spin-echo and echo-planar imaging of the head and neck.
Mikayama, Ryoji; Yabuuchi, Hidetake; Sonoda, Shinjiro; Kobayashi, Koji; Nagatomo, Kazuya; Kimura, Mitsuhiro; Kawanami, Satoshi; Kamitani, Takeshi; Kumazawa, Seiji; Honda, Hiroshi.
Afiliação
  • Mikayama R; Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higasi-ku, Fukuoka, 812-8582, Japan.
  • Yabuuchi H; Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higasi-ku, Fukuoka, 812-8582, Japan. h-yabu@med.kyushu-u.ac.jp.
  • Sonoda S; Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higasi-ku, Fukuoka, 812-8582, Japan.
  • Kobayashi K; Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higasi-ku, Fukuoka, 812-8582, Japan.
  • Nagatomo K; Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higasi-ku, Fukuoka, 812-8582, Japan.
  • Kimura M; Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higasi-ku, Fukuoka, 812-8582, Japan.
  • Kawanami S; Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higasi-ku, Fukuoka, 812-8582, Japan.
  • Kamitani T; Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higasi-ku, Fukuoka, 812-8582, Japan.
  • Kumazawa S; Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higasi-ku, Fukuoka, 812-8582, Japan.
  • Honda H; Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higasi-ku, Fukuoka, 812-8582, Japan.
Eur Radiol ; 28(1): 316-324, 2018 Jan.
Article em En | MEDLINE | ID: mdl-28779394
ABSTRACT

OBJECTIVES:

To compare image quality, apparent diffusion coefficient (ADC), and intravoxel incoherent motion (IVIM)-derived parameters between turbo spin-echo (TSE)-diffusion-weighted imaging (DWI) and echo-planar imaging (EPI)-DWI of the head and neck.

METHODS:

Fourteen volunteers underwent head and neck imaging using TSE-DWI and EPI-DWI. Distortion ratio (DR), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), ADC and IVIM-derived parameters were compared between the two techniques. Bland-Altman analysis was performed to analyse reproducibility between the quantitative parameters of TSE-DWI and EPI-DWI.

RESULTS:

DR of TSE-DWI was significantly smaller than that of EPI-DWI. SNR and CNR of TSE-DWI were significantly higher than those of EPI-DWI. ADC and IVIM-derived parameters of TSE-DWI showed higher values than those of EPI-DWI, although the difference was not significant. Bland-Altman analysis showed wide limits of agreement between the two sequences.

CONCLUSION:

TSE-DWI can produce better image quality than EPI-DWI, while TSE-DWI possibly exhibits different values of quantitative parameters. Therefore, TSE-DWI could be a good alternative to EPI-DWI for patients sensitive to distortion. However, it is not recommended to use both TSE-DWI and EPI-DWI on follow-up. KEY POINTS • Head and neck DWI is especially sensitive to magnetic inhomogeneity. • The distortion of images was less with TSE-DWI than with EPI-DWI. • TSE-DWI can possibly exhibit higher ADC and IVIM-derived parameters than EPI-DWI. • Bland-Altman analysis showed unacceptable LoA in quantitative analysis between TSE-DWI and EPI-DWI. • It is not recommended to use both TSE-DWI and EPI-DWI for follow-up.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imagem Ecoplanar / Imagem de Difusão por Ressonância Magnética / Cabeça / Pescoço Limite: Adult / Female / Humans / Male Idioma: En Revista: Eur Radiol Assunto da revista: RADIOLOGIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imagem Ecoplanar / Imagem de Difusão por Ressonância Magnética / Cabeça / Pescoço Limite: Adult / Female / Humans / Male Idioma: En Revista: Eur Radiol Assunto da revista: RADIOLOGIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Japão