Your browser doesn't support javascript.
loading
[Initial study of transthoracic echocardiography guided three-dimensional printing on the application of assessment of structural heart disease].
Zhu, Y B; Liu, J S; Wang, L Q; Guan, X; Luo, Y J; Geng, J; Geng, Q G; Lin, Y J; Zhang, L X; Li, X X; Lu, Y P.
Afiliação
  • Zhu YB; Graduate School of Tianjin Medical University, Tianjin 300070, China.
Zhonghua Yi Xue Za Zhi ; 97(29): 2280-2283, 2017 Aug 01.
Article em Zh | MEDLINE | ID: mdl-28780843
ABSTRACT

Objective:

To investigate the feasibility and diagnostic value of preoperative transthoracic echocardiography guided three dimensional printing model (TTE Guided 3DPM) on the assessment of structural heart disease (SHD).

Methods:

From February 2016 to October 2016, 44 patients underwent cardiac surgery in Tianjin Chest Hospital, forty-four patients were assessed preoperatively using TTE Guided 3DPM, including 25 males and 19 females, aged 3-75 years, with an average of (44±22) years. compared to conventional three dimensional transthoracic echocardiography (3D-TTE), and took direct intraoperative findings as "Golden Standard" simultaneously. There are twelve patients with SHD, including four cases with mitral prolapse, two cases with partial endocardial cushion defect, two cases with secondary atrial septal defect, two cases with rheumatic mitral stenosis, one case with tetralogy of Fallot, one case with ventricular septal defect (VSD), thirty-two patients without SHD were designed as negative control.

Results:

The sensitivity and specificity of TTE Guided 3DPM were greater than or equal to 3D-TTE, P value of McNemar test of 3D-TTE was greater than 0.05, the difference was not statistically significant, kappa=0.745, P<0.01, indicated that the results of 3DTTE and the gold standard were generally consistent.P value of McNemar test of TTE Guided 3DPM was greater than 0.05, the difference was not statistically significant, kappa=0.955, P<0.01, indicated that the results of TTE Guided 3DPM and gold standards were consistent. Compared with 3D-TTE and TTE Guided 3DPM, P value was greater than 0.05, the difference was not statistically significant, kappa=0.879, P<0.01, indicated that the results of 3D-TTE and TTE Guided 3DPM were consistent. TTE Guided 3DPM displayed the three-dimensional structure of SHD cardiac lesions clearly, which were consistent with intraoperative findings.

Conclusion:

TTE Guided 3DPM provides essential information for the preoperative evaluation and decision of SHD.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ecocardiografia / Ecocardiografia Tridimensional Tipo de estudo: Guideline / Prognostic_studies Limite: Adolescent / Adult / Aged / Child / Child, preschool / Female / Humans / Male / Middle aged Idioma: Zh Revista: Zhonghua Yi Xue Za Zhi Ano de publicação: 2017 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ecocardiografia / Ecocardiografia Tridimensional Tipo de estudo: Guideline / Prognostic_studies Limite: Adolescent / Adult / Aged / Child / Child, preschool / Female / Humans / Male / Middle aged Idioma: Zh Revista: Zhonghua Yi Xue Za Zhi Ano de publicação: 2017 Tipo de documento: Article País de afiliação: China