Your browser doesn't support javascript.
loading
A Recyclable Metal-Organic Framework as a Dual Detector and Adsorbent for Ammonia.
Gladysiak, Andrzej; Nguyen, Tu N; Navarro, Jorge A R; Rosseinsky, Matthew J; Stylianou, Kyriakos C.
Afiliação
  • Gladysiak A; Laboratory of Molecular Simulation (LSMO), Institut des Sciences et Ingénierie Chimiques (ISIC), Ecole Polytechnique Fédérale de Lausanne (EPFL Valais), Rue de l'Industrie 17, 1951, Sion, Switzerland.
  • Nguyen TN; Laboratory of Molecular Simulation (LSMO), Institut des Sciences et Ingénierie Chimiques (ISIC), Ecole Polytechnique Fédérale de Lausanne (EPFL Valais), Rue de l'Industrie 17, 1951, Sion, Switzerland.
  • Navarro JAR; Departamento de Química Inorgánica, Universidad de Granada, Av. Fuentenueva S/N, 18071, Granada, Spain.
  • Rosseinsky MJ; Department of Chemistry, University of Liverpool, Liverpool, L69 7ZD, UK.
  • Stylianou KC; Laboratory of Molecular Simulation (LSMO), Institut des Sciences et Ingénierie Chimiques (ISIC), Ecole Polytechnique Fédérale de Lausanne (EPFL Valais), Rue de l'Industrie 17, 1951, Sion, Switzerland.
Chemistry ; 23(55): 13602-13606, 2017 Oct 04.
Article em En | MEDLINE | ID: mdl-28786536
ABSTRACT
Recyclable materials for simultaneous detection and uptake of ammonia (NH3 ) are of great interest due to the hazardous nature of NH3 . The structural versatility and porous nature of metal-organic frameworks (MOFs) make them ideal candidates for NH3 capture. Herein, the synthesis of a water-stable and porous 3-dimensional CuII -based MOF (SION-10) displaying a ship-in-a-bottle structure is reported; the pores of the host SION-10 framework accommodate mononuclear CuII -complexes. SION-10 spontaneously uptakes NH3 as a result of two concurrent mechanisms chemisorption due to the presence of active CuII sites and physisorption (bulk permanent porosity). The color of the material changes from green to blue upon NH3 capture, with the shifts of the UV/Vis absorption bands clearly seen at NH3 concentrations as low as 300 ppm. SION-10 can be recovered upon immersion of SION-10⊃NH3 in water and can be further reused for NH3 capture for at least three cycles.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Chemistry Assunto da revista: QUIMICA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Suíça

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Chemistry Assunto da revista: QUIMICA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Suíça