Your browser doesn't support javascript.
loading
Dosing of indocyanine green for intraoperative laser fluorescence angiography in kidney transplantation.
Rother, Ulrich; Gerken, Andreas L H; Karampinis, Ioannis; Klumpp, Madeline; Regus, Susanne; Meyer, Alexander; Apel, Hendrik; Krämer, Bernhard K; Hilgers, Karl; Lang, Werner; Nowak, Kai.
Afiliação
  • Rother U; Department of Vascular Surgery, University of Erlangen, Erlangen, Germany.
  • Gerken ALH; Department of Surgery, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany.
  • Karampinis I; Department of Surgery, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany.
  • Klumpp M; Department of Vascular Surgery, University of Erlangen, Erlangen, Germany.
  • Regus S; Department of Vascular Surgery, University of Erlangen, Erlangen, Germany.
  • Meyer A; Department of Vascular Surgery, University of Erlangen, Erlangen, Germany.
  • Apel H; Department of Urology, University of Erlangen, Erlangen, Germany.
  • Krämer BK; Department of Medicine V, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany.
  • Hilgers K; Department of Nephrology, University of Erlangen, Erlangen, Germany.
  • Lang W; Department of Vascular Surgery, University of Erlangen, Erlangen, Germany.
  • Nowak K; Department of Surgery, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany.
Microcirculation ; 24(8)2017 11.
Article em En | MEDLINE | ID: mdl-28787770
ABSTRACT

OBJECTIVE:

Sufficient blood supply is a crucial factor determining postoperative allograft function in kidney transplantation. Therefore, besides the surgeon's individual impression, a method for evaluating the quality of the organ's microperfusion is required. Laser fluorescence angiography with indocyanine green (ICG) is an emerging tool for this purpose. However, no reproducible quantification of ICG fluorescence has been performed in transplantation so far.

METHODS:

This retrospective two-center study was designed to evaluate the dosing of ICG for intraoperative laser fluorescence angiography in kidney transplantation. The Spy Elite® system (NOVADAQ, Canada) was employed for quantitative assessment of allograft microperfusion. ICG was administered systemically 5 minutes after reperfusion applying doses between 0.25 and 0.01 mg ICG per kg body weight. Quantitative assessment was performed with the implemented SPY-Q Software.

RESULTS:

A total of 57 kidney recipients were included in two centers. The generated curves showing ICG IN and EgR were not evaluable due to oversensing when doses exceeded 0.02 mg per kg body weight.

CONCLUSIONS:

Fluorescence angiography with ICG is an emerging tool for the intraoperative quality control and evaluation of microperfusion in kidney transplantation. A dose of 0.02 mg ICG per kg body weight is recommended to ensure the quantitative assessment with SPY-Q.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Angiofluoresceinografia / Transplante de Rim / Verde de Indocianina / Cuidados Intraoperatórios / Lasers Tipo de estudo: Observational_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Microcirculation Assunto da revista: ANGIOLOGIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Angiofluoresceinografia / Transplante de Rim / Verde de Indocianina / Cuidados Intraoperatórios / Lasers Tipo de estudo: Observational_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Microcirculation Assunto da revista: ANGIOLOGIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Alemanha